2-2 DRY operation
ADDRESS
UNIT No.
FUNCTION No.
SELECTION No.
FUNCTION
TEST RUN
CHECK
ON/OFF
<DRY operation time chart>
Operation starts by
P O W E R b u t t o n
ON.
ON
OFF
Thermostat
ON
Indoor fan
OFF
CLOSE
Auto vane
ON
Booster heater
OFF
ON
Compressor
OFF
w1 Even if the room temperature rise above the set temperature during this period, the compressor will not start until this period
has ended.
OC229A
°C
AM
PM
AM
PM
TEMP.
Room temperature
becomes equal to
set temperature.
LOW speed
Initally 10 degrees discharge
( Changeable by remote controller setting )
OFF
<How to operate>
1 Press POWER ON/OFF button.
2 Press the MODE button to display "
i
3 Press the
TEMP. button to set the desired temperature.
NOTE: The set temperature changes 1°C when the
button is press one time DRY 19 to 0°C.
Room temperature
rises above set
temperature.
Minimum 3 minutes
1
2
2
e
".
Operation stops by
P O W E R b u t t o n
OFF.
LOW speed
CLOSE