Page 1
Surveyor® MKII Analog Camera Domes XX283-30-01 Vicon Industries Inc. Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet Tel: 631-952-2288) Fax: 631-951-2288 your requirements or that the operation will be entirely error free or perform precisely as Toll Free: 800-645-9116 described in the documentation.
Page 2
The Surveyor MKII Analog PTZ Domes have been tested and found to comply with the limits for a Class A digital device, pursuant to the FCC rules. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Page 3
Read this manual carefully before installation. This manual should be saved for future use. Important Safety Instructions and Warnings Electronic devices must be kept away from water, fire or high magnetic radiation. Clean with a dry cloth. Provide adequate ventilation.
1.1 Product Description receive the alarm signal from the external devices. Vicon's Surveyor MKII is a compact analog PTZ dome camera When no command is received for a programmable period of time, comprised of a camera/lens and pan/tilt drive in an attractive covert the domes can be programmed to automatically return to "home...
Upon alarm, the domes will automatically return to a certain preset. The Surveyor MKII analog domes are compatible with Vicon The preset to call upon alarm, as well as the normal state...
3.2 Basic Operations NEAR The Surveyor MKII analog domes can be easily controlled via a Focus Far Press the FOCUS FAR key to manually adjust Vicon keypad (ex., V1411) controller or a Vicon VMS. Listed in the focus on distant objects.
The following are guidelines for defining and calling the four auto 3. Press PRESET button, then press number keys (1-79), and then tours with Vicon system keypad using Vicon protocol. press PRESET button to store the settings. To define an Auto Tour 1.
Press & hold Press the number key Release Press "PRESET+8+9+PRESET" to call up Auto Tour 4. Note: Vicon control protocol only allows one autopan to be programmed. 3.5 Setting and Calling up Autopan With the AUTOPAN features, the domes can automatically move...
4.2 MAIN MENU Chapter IV Menu Programming 1. SYS-INFO SET The Analog Domes feature OSD menus for setting up various 1.1 SYSTEM SET operation parameters. To utilize functions like AUTOPAN, home Display the current S/N number position, area partition and privacy mask, appropriate settings Display the camera ID number ...
Page 10
2.2 IRIS SET 3.3 AUTO TOUR SET Set iris mode Enable/disable auto tour display Set iris level Auto tour number Set iris default level Set auto tour title Clear title 2.3 FOCUS SET ...
4.4 COMPASS DISPLAY Enable/disable Compass display SYSTEM SET Set Title position CURRENT S/N 11111111111 MODEL : SV36S CAM ADDR 4.5 SYNC SET BROAD ID : V-I-D-P PROTOCOL: Enable/disable Compass display BAUD RATE : 2400 Set Title position ...
Page 12
4.3.2 DOME TITLE SET HUMIDITY Function: Turn the Humidity title ON/OFF. DOME TITLE SET PRESSURE Function: Turn the Pressure display ON/OFF. TITLE SET: Only available on pressurized model dome. ROW : COLUMN : PRESSURE ALARM TITLE DISP Function: Enable/Disable the Pressure Loss Alarm. TITLE CLEAR: Only available on pressurized model dome.
4.4.1 ZOOM SET 4.3.7 DATE AND TIME SET DIGITAL ZOOM Function: Enable/disable digital zoom. TIME DIS Options: OFF –Disable digital zoom function (default). Function: Turns the Time display ON/OFF. ON – Enable digital zoom function. DATE FORMAT Function: Change the Date format YYYY/MM/DD, ZOOM SPEED DD/MM/YYYY or MM/DD/YYYY.
Page 14
4.4.3 FOCUS SET WB-B Function: Allow manual adjustment of B-gain value for customer FOCUS SET white balance. 30cm FOCUS LIMIT: Options: 000 ~ 255 -The color shift will be viewed on the FOCUS MODE: monitor when changing the B-gain value. The greater RETURN EXIT the number is, the more bluish the picture becomes.
Page 15
Function: Turn on/off the backlight compensation feature. A sharp contrast of brightness and darkness may arise when a bright backlight is present. This usually leads to a vague dark or even silhouetted image of a subject under surveillance. Under such circumstances, the backlight compensation can be used to achieve a suitable exposure level so as to get a clear view of the subject.
(via keypad commands). Note: Vicon control system only supports 1 autopan and this is set The domes support 254 presets, but only 79 can be accessed by the up initially using the keypad. (Store Preset 98 Preset).
3. Move the cursor to the next character. TITLE SET 4. Repeat steps 2 and 3 to complete the title. Function: Set title for the selected AUTOPAN (up to 16 characters). TITLE CLEAR Display can be set to display or not. If set to ON, the title will Function: Clear some or all of the titles.
PST 19 – Call up Preset 19 for restarting after power off. 4.5.7 SCHEDULER 4.5.5 NORM TOUR SET NORM TOUR SET TOUR NO : 001 ACT TIME ACT TIME 1 000 3 000 5 000 7 000 9 000 11 000 13 000 RETURN EXIT...
4.6.1 MASK SET PRIVACY MASK Function: Turn on/off Privacy Mask function. Options: OFF – Enable the Privacy Mask function (default). MASK SET ON – Disable the Privacy Mask function. ============== PRIVACY MASK MODE 1 PRIVACY MASK MODE 2 MASK NO. RETURN Function: Selected the area to be masked.
3. After the width and height are set, press “AUX2” to save the RESET ACTION current width and height of the mask area. Function: Set a Reset action that occurs once the alarm has been 4. After exiting the menu, in joystick PTZ operations, the set acknowledged.
Page 21
sectors covering the boarding gates (Sectors 5 and 6) are much SECTOR SET larger than those covering the escalators (Sectors 1 and 2). Function: Set sector boundaries. Details are addressed below. The zoom level may also affect the sector size during camera How to set sector boundaries: operations.
4. Move the camera until the enlarged image of the boundary point is displayed in the screen center. 5. Enter the appropriate code commands to set the boundary. If the DISPLAY option has been set "ON" in the SECTOR SET menu, overlay texts indicating sector number and title description will be displayed as long as the camera view stays in the sector.
PHASE ADJUST Function: Manually adjust the line phase. Option: 1-198 4.6.6 MOTION CONTROL THRESHOLD Function: Sets the amount of activity required to generate an Alarm. Option: 0 – 255. The lower the value the more sensitive the detection. INTERVAL The dome capable of Motion Detection and can be enabled and Function: Sets the amount of time that motion must occur before configured in the following steps.
Set pattern 3 The following table shows the performances and features of the OPERATE Call pattern 3 (cycle) domes under protocols. PROGRAM Set pattern 4 PELCO-P/ PELCO-D/VICON OPERATE Call pattern 4 (cycle) Baud Rate 2400/4800/9600/19200BPS PROGRAM Set/save autopan 1 Camera Addresses...
Appendix I Specifications The following table describes the general parameters of the Surveyor MKII Analog Domes. Programmable Presets Programmable Auto Tours Programmable Autopans Programmable Sectors Video Blanking Sectors Spherical Privacy Zones Tour Alarm Inputs 4 alarm inputs Alarm Outputs 1 relay output...
Page 26
Technical Specification of the Cameras Optic Zoom Video Type NTSC/PAL (D/N) Scanning System 2:1 Interlace scanning Image Sensor 1/4" Progressive scanning CCD NTSC/380K: 768×494 Resolution (HxV) PAL/440K: 752×582 Aperture/Focal Length F1.6~F4.5; f=3.4~122.4mm Angle of View 57.8° (Wide) / 1.7° (Tele) Min.
Appendix II Troubleshooting The following table describes the symptoms, causes, and solutions for the problems. Symptoms Possible Causes Solutions Wrong power connection Reconnect power cable Unit does not perform initiation sequence after Power supply failure Repair or replace power supply powering on Power PCB fuse damage Replace the fuse...
Page 28
“autopan” or “tour” modes of operation. Such continuous operation is outside the scope of this warranty. 11. Any product sold as “special” or not listed in Vicon’s commercial price list: One year from date of original retail purchase.
Page 29
Software supplied either separately or in hardware is furnished on an “As Is” basis. Vicon does not warrant that such software shall be error (bug) free. Software support via telephone, if provided at no cost, may be discontinued at any time without notice at Vicon’s sole discretion. Vicon reserves the right to make changes to its software in any of its products at any time and without notice.
Page 30
VICON INDUSTRIES INC. For office locations, visit the website: www.vicon-security.com...
Need help?
Do you have a question about the Surveyor MKII and is the answer not in the manual?
Questions and answers