Vicon SurveyorVFT SVFT-M Installation And Operation Manual

Maximum security camera dome

Advertisement

Warning: To reduce a risk of fire or electric shock, do not expose
the indoor unit to rain or moisture.
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your
requirements or that the operation will be entirely error free or perform precisely as described in the
documentation. This system has not been designed to be used in life-critical situations and must not be
used for this purpose.
Copyright © 2008 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
SurveyorVFT and Kollector are trademarks and ViconNet a registered trademark of Vicon Industries Inc.
ExView is a trademark of Sony Corporation.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300
Vicon part number 8009-8157-14-00
SVFT-M Maximum Security
WEB: www.vicon-cctv.com
XX157-14-00
Camera Dome
Section 3 Rev 908

Advertisement

Table of Contents
loading

Summary of Contents for Vicon SurveyorVFT SVFT-M

  • Page 1 Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation.
  • Page 3 The product shows a significant change in performance. 6. Attachments - Use only UL Listed Vicon recommended attachments to prevent unit damage and personal injury. 20. Replacement Parts - Use only Vicon specified replacement 7.
  • Page 5: Fcc Notice

    FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNING This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception.
  • Page 7: Table Of Contents

    Contents INTRODUCTION........................1 How to Use this Manual ..........................3 Accessory Kits..............................4 Unpacking and Inspection..........................4 SVFT-M Components .............................6 Housing ..............................6 Camera Drive ............................6 Shroud...............................6 Lower Dome ..............................6 Sunshield..............................6 INSTALLATION ........................8 Quick Installation............................8 Detailed Installation ............................9 WIRING..........................13 Typical Relay and Alarm Connections .......................15 Installing the Cables ............................16 Installation Configurations..........................20 Installing the Flash Upgrade and PC Direct Control ................21...
  • Page 8 REFERENCE ........................50 Coaxial Cable Recommendations ......................50 Twisted-Pair Cable............................51 1.5-inch Pipe Designation ........................... 51 Network Cable .............................. 52 TECHNICAL INFORMATION..................... 53 VICON STANDARD EQUIPMENT WARRANTY ............... 58 iv • 2BContents XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 9: Introduction

    LAN interface board allows direct plug-in to a system network hub, switch or router. Video from the camera is available to all network recorders and workstations for live view and recording. The Vicon SVFT-M camera dome can be used in conjunction with competitive PTZ drivers through DIP switch selection. Audio input capability is available on the ViconNet version.
  • Page 10 Table 1 Models and Descriptions Model Number Product Environment/ Camera Mount Optical Zoom/ Lower Dome Code Cable Type Type/Format Type Total Zoom Type SVFT-M22 8747-00 Outdoor/Coax Color/NTSC Pendant 22x/264x Clear Polycarbonate SVFT-M22-C 8747-01 Outdoor/Coax Color/PAL Pendant 22x/264x Clear Polycarbonate SVFT-M22E 8748-00 Outdoor/Coax Color/NTSC...
  • Page 11: How To Use This Manual

    How to Use this Manual This manual was designed to provide the best overall instructions for the installation and operation of the SurveyorVFT Maximum Security Camera Dome. The graphics and terminology used in this manual have been carefully selected to enable a clear and distinct understanding of the SVFT-M and its components. This manual has been formatted to present distinct methods of installation for qualified service personnel only.
  • Page 12: Accessory Kits

    Installation section for details on applying the lubricant. Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier’s responsibility to provide suitable delivery. Inspect the cartons upon delivery and, if damage is present, make detailed notes on the carrier’s bill. Then, obtain the carrier agent’s signature and file a damage claim as soon as possible.
  • Page 13 Unpacking the SVFT-M 3BIntroduction • 5 XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 14: Svft-M Components

    SVFT-M Components All SVFT-M units are comprised of a Rugged Housing, a Camera Drive, a Shroud and a Lower Dome. Figure 1 shows these components. Housing The housing for the SVFT-M has a die-cast aluminum housing with a sunshield. The housing has a 1.5-inch NPT pipe flange mount. In addition, the housing is equipped with a safety cord and clip that is used to suspend the camera drive during installation.
  • Page 15 3BIntroduction • 7 XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 16: Installation

    Installation Quick Installation 8 • 4BInstallation XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 17: Detailed Installation

    These steps provide the most thorough and accurate instructions The SVFT-M model mounts on a Vicon mount (refer to the Introduction section) or a 1.5-inch vertical pipe with appropriate coupling. The pipe is a standard 1.5-inch NPT type and must be oriented vertically so the SVFT-M can effectively hang from the pipe.
  • Page 18 a) Strip approximately 1 inch (25 mm) of the cable outer jacket to be terminated in terminal blocks TB1 and TB3. Then strip approximately 0.25 inches (6 mm) of insulation off of each individual wire. b) Refer to Wiring section and Table 2 to make all connections to terminal block TB1 (power), TB2 (alarms), TB3 (relays/control signals) and TB4 UTP video).
  • Page 19 14. Push camera drive straight up into the housing until snaps into housing. excessive force. In the event that it does not snap easily, remove the SVFT-M and verify proper cabling. 15. Holding the lower dome, line up the 2 molded tabs on the lower dome with...
  • Page 20 Figure 5 Lower Dome Installation 12 • 4BInstallation XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 21: Wiring

    Table 4 of the Technical Information section. Refer to the table in the Introduction for power supplies available from Vicon (single and multi-channel). In the standard version, video cables carry the composite video signal and Vicoax signals out of the SVFT-M over coaxial cable.
  • Page 22 Figure 6 Customer Interface Board Connections 14 • 5BWiring XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 23: Typical Relay And Alarm Connections

    Typical Relay and Alarm Connections Alarm input and relay output type signals are also carried on individually-shielded twisted-pair cable sets. The signals are defined in the following descriptions. Alarms 1-4 are electronic CMOS level type inputs that are driven by a dry contact type switch. These signals are connected to terminal block TB2.
  • Page 24: Installing The Cables

    Installing the Cables WARNING: Disable the AC power to prevent installer injury and damage to the unit. Cables are routed from the inside of the housing to the customer interface board. In all cases, there should be minimal wire slack at all connection points. After wiring is complete, dress the cables so they are up over the board.
  • Page 25 CONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAME CONNECTOR/PIN NUMBER BNC (female) VIDEO (J1) Video output VIDEO AMP Header (Fiber Optic board)* Video/RS-422 data TERMINAL BLOCK POWER (TB1) TB1-1 TB1-2 Neutral TERMINAL BLOCK ALARM (TB2) TB2-1 Alarm input 1 ALARM 1 TB2-2 Ground TB2-3 Alarm input 2...
  • Page 26 CONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAME CONNECTOR/PIN NUMBER TERMINAL BLOCK VIDEO NVT (TB4) TB4-1 Unshielded twisted pair + UTP + TB4-2 Unshielded twisted pair - UTP - TB4-3 TERMINAL BLOCK POWER (TB1) TB1-1 TB1-2 Neutral TERMINAL BLOCK ALARM (TB2) TB2-1 Alarm input 1 ALARM 1 TB2-2...
  • Page 27 CONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAME CONNECTOR/PIN NUMBER TERMINAL BLOCK POWER (TB3) TB3-1 TB3-2 Neutral TERMINAL BLOCK ALARM (P1) P1-1 Alarm output ALARM OUT P1-2 Ground P1-3 Alarm input ALARM IN RJ-45 LAN (J7) J7-1 Transmit + TX + J7-2 Transmit - TX - J7-3...
  • Page 28: Installation Configurations

    The star configuration requires the use of a Distribution Line Control, such as Vicon’s V1400X-IDL that can support up to 10 domes. Refer to the figure below for an illustration of sample configurations. Both types of configurations can be used within a system.
  • Page 29: Installing The Flash Upgrade And Pc Direct Control

    SVFT-M data line. When one PC is being used with one dome, the PC must be connected to the SVFT-M by means of Vicon’s RS-232/RS-422 Interface Converter (part number 1240-5308-01) and a cable assembly (not provided). Fabricate the cable using 2 twisted pairs plus shield. See table below for pin out connections.
  • Page 30: Star Configuration

    Standalone Configuration System Star Configuration When multiple domes are connected in a star configuration, using a V1400X-IDL, the RS-232/RS-422 Interface Converter is used, part number 1240-5308-01, along with a customer fabricated cable. Refer to Table 2A for connections. In this configuration, connect the converter end of the customer-fabricated cable assembly to the SERIAL port of the computer and the other end to the CPU/J11 port on the V1400X-IDL (you may have to disconnect the keypad).
  • Page 31 Star Configuration System After the physical connections are made, insert the software disk and select the appropriate program, Flash Upgrade Utility or PC Direct Control Software. 5BWiring • 23 XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 32: Configuration

    Configuration The SVFT-M must be configured for its address and mode and termination setting when using RS-422/RS- 485 protocol. The address and mode are set using the two 8-position DIP Switch banks SW1 and SW2. It is necessary to determine which communication mode, Camera/Lens Module type and SurveyorVFT address is required prior to configuration.
  • Page 33 NOTE: DIP switches labeled ON or CLOSED and OFF or OPEN have the same meaning. Figure 10 DIP Switch Label Competitive Protocol Settings, SW2 Switches 5-8 Pelco: Switch 5 is ON, switches 6-8 are OFF Sensormatic: Switch 6 is ON, switches 5, 7, 8 are OFF Ultrak: Switches 5 and 6 are ON, switches 7-8 are OFF Philips: Switch 7 is ON, switches 5, 6, 8 are OFF Cohu: Switches 5 and 7 are ON, switches 6 and 8 are OFF...
  • Page 34 DIP Switch 1 (SW1) Address (NOVA/VPS Mode) SWITCHES SWITCHES SWITCHES Table 3 DIP Switch 1 (SW1) Settings for NOVA/VPS Mode 26 • 6BConfiguration XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 35: Setting The End-Of-Line Jumpers Jp1, Jp2 & Jp3 For Rs-485 Protocol Operation

    Setting the End-of-Line Jumpers JP1, JP2 & JP3 for RS-485 Protocol Operation This section defines setting the end-of-line jumpers JP1, JP2 and JP3. The jumper sockets are located on the underside of the customer interface board, shown in Figure 11. Figure 11 End-of-Line Jumper Location NOTE: DIP Switch 2 (SW2) switch 4 must be set to the ON (RS-485) position for proper daisy chain...
  • Page 36: Configuring The Network Settings

    When adding a SVFT-M IP Camera to the ViconNet network, the following items must be considered: • The number of cameras on a switch with respect to switch capabilities and system bandwidth mapping. • Bandwidth limitations on ports connected to workstations (using 100 or 1000 Mbps). •...
  • Page 37 C:\VUG.) In Password file status, the number of passwords stored is displayed. Load a list of passwords is intended for very large sites only. Contact Technical Support to use this feature. Setup Select TAB The Select TAB allows the user to select the relevant IP Unit in order to change its settings or to upgrade its version.
  • Page 38 Select Unit TAB The Unit TAB allows the user to change the following settings: Unit name, Nucleus IP address, IP address, Net mask, Gateway, DNS, DHCP, Time Zone, daylight saving time, Local time, Local date, and Debug level, on a scale of 0-4, where 4 is most information. Note: The Apply button must be pressed for changes to take effect.
  • Page 39: Advanced Tab

    Install TAB The Install TAB allows the user to install/upgrade newer versions. Choose the correct version and click Install to send to the selected unit. Install Info Tab The Info TAB displays the selected IP product general information/ Info Advanced TAB The Advanced TAB functionalities allow the user to handle unexpected events on a specific remote unit when they occur.
  • Page 40 Advanced Custom TAB The Custom TAB is only used for the KRX-3 Decoder. Do NOT do any settings in this screen. Custom After the SurveyorVFT has been configured for ViconNet, upon another boot up (or preset 97), the opening screen will display (see below). This screen displays the camera dome program version, current date/time and some of the word ViconNet.
  • Page 41: Viconnet Configuration

    ViconNet Configuration After the camera dome has been setup with the proper IP address, configuration features from a remote workstation, server or recorder are available as follows. • A network settings screen is used to modify the camera dome’s IP parameters. This allows great flexibility in network setup.
  • Page 42: Viconnet (Ip/Lan) Version Operation

    ViconNet (IP/LAN) Version Operation The following functions are supported by the ViconNet system through a workstation, recorder or server. 1. System macros can be configured to view and record the dome’s video. In addition, within macros, alarms can be sent and remote macros triggered. 2.
  • Page 43: Uninstalling The Svft-M

    Uninstalling the SVFT-M The SVFT-M camera drive can be easily uninstalled by simply pushing in the tabs to release the camera drive from the housing or the enclosure. A safety cord is always available to safely hang the camera drive or camera dome assembly while installing or uninstalling.
  • Page 44: Operation

    When initial power-up has been completed and verified, SVFT-M can be setup and operated in a normal fashion using a Vicon remote operator keypad, VPS/NOVA unit or through a PC running the Surveyor Direct Control program; the ViconNet can be run from a ViconNet workstation.
  • Page 45: Verifying Proper Operation

    SVFT-M. Power-on the control device and verify that it boots up. Set up the control device for operation with the SVFT-M in accordance with its Installation and Operation Manual. For a Vicon model V1300X-RVC or V1300X-DVC keypad connected directly to the SVFT-M or through a CPU, use the following procedure to access SVFT-M programming: 1.
  • Page 46: Troubleshooting

    2. Press the PP ENTER key; the PRESET LED displays a blinking 0. 3. Press the 9 and 5 numeric keys in that order. 4. Press the PP ENTER key again. The PRESET LED display remains with the number 95. The monitor will display the power-up test screen (Figure 13) for the duration of its initial testing.
  • Page 47: Competitive Protocols

    Note: All companies make changes and improvements in their products. Because this product can interface with equipment not manufactured by Vicon, there is a possibility that the interface protocols may have changed since Vicon tested this product with the interfacing equipment. Vicon recommends purchasing a single unit for bench testing prior to purchasing and installing this product in quantity.
  • Page 48 Pelco 40 • 9BCompetitive Protocols XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System...
  • Page 49 Focus Far Debug Screen Focus Far The controller MPT9500 doesn't support Pelco tours. Vicon's tours are accessible using presets 80-87 or the menu system. To store a tour, Enter preset number, Preset Set , F2. To run tour use Zoom Out Preset Tours Preset Go.
  • Page 50 Repeat Pattern to repeat. Camera Off Not Supported Night Mode- Manual Not Supported Vicon Menu Alarms are not used. Alarms are alw ays enabled. The dome w ill report to the AD keypad w hich alarm is activated (1-4) Camera On...
  • Page 51 Kalatel Function Keypress Function Keypress Press Set until "Enter Programming Code" appears. Enter Access Code 951followed by SEQ. Select 4 - Cyberdome. Enter three digit camera number. Enter 1 when prompted "Does The Monitor Display Site XXX". Enter Menu Program the unit using the joystick. Set Transmit Polarity Not Supported Not Supported;...
  • Page 52 Ultrak When changing SVFT-M software addresses, the keypad may not respond to all 256 addresses. The workaround is to go to Ultrak KEGS Setup menu, option (3.1.2) and set every camera (256) to KD6. Function Keypress Function Keypress Enter SVFT-M address on keypad and hit Enter key.
  • Page 53 Panasonic Function Keypress Function Keypress Press and hold CAMERA SETUP button for 2 sec. Use SET button to select and save options. Use ESC button to abort or leave options. Move joystick up and down to select and highlight SurveyorVFT preset 94 menu options. Use button AUX 1 for Aux 1 and AUX 2 for Aux 2.
  • Page 54 Philips Function Keypress Function Keypress Use On-46-Enter shortcut to enter Dome menu. Use Focus Far button to select and save options. Use Iris Close button to abort or leave options. Move joystick up and down to select and highlight Dome menu options (joystick does not support "press and hold"...
  • Page 55 Cohu Function Keypress Function Keypress To launch Dome menu use Preset 64 + Store. Use Focus Far button to select and save options. Use Iris Close button to abort or exit options. Move mouse cursor up and down on Not Supported Pan/Tilt pane to select and highlight Dome menu options.
  • Page 56: Maintenance

    Maintenance The SVFT-M requires no scheduled maintenance; however, the Lower Domes require occasional cleaning. Domes require careful handling and occasional cleaning. Care and Cleaning of Polycarbonate Domes 1. Always handle the lower dome by the flange and avoid touching the inside surface. 2.
  • Page 57: Shipping Instructions

    Use the following procedure when returning a unit to the factory: low. Record the name 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed be of the Vicon employee who issued the R.A.
  • Page 58: Reference

    Coaxial Cable Recommendations Caution: Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.
  • Page 59: Twisted-Pair Cable

    Twisted-Pair Cable CAUTION: Careful selection of the proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended are installed. Materials se a pure copper stranded conductor with or without a tin plating to obtain a low DC resistance.
  • Page 60: Network Cable

    Network Cable Caution: Careful selection of proper cable is essential to obtain the best performance. Vicon assumes no responsibility for poor performance when cables other than the recommended types, or equivalent, are used. aterials Use pure copper stranded conductors to obtain a low DC resistance. The preferred insulation and cable jacket is Polyvinyl chloride (PVC).
  • Page 61: Technical Information

    Technical Information Zoom and Focus Speed: Less than 1.8 sec from end to end. ELECTRICAL Drive Type: Electrical motorized pan and tilt Sectoring: 16 max, programmable for size and with electronic control. titling; capability to be blanked out (22XEX, 23X and 35X only). Came ra Types: Units available in color and day/night...
  • Page 62 (not Because this product can interface on 22X). with equipment not manufactured by Vicon, there is a possibility that the Multilanguage M nu English, Spanish, French, German interface protocols have and Italian.
  • Page 63 4 in./hr at winds up Authentication: 0 mph, when mounte d on video from t he camera dome is standard Vicon w all mount. t to view the Authentication status Picture Quality and FPS mbol (A) on the displayed video.
  • Page 64 Table 5: Camera/Lens Specifications Model Numbers VFT-M22E SVFT-M22EC SVFT-M23 SVFT-M23C Product Codes Camera Specifications 8748-00 8748-01 8749-00 8749-01 Formats NTSC NTSC Type Color Color Color Color Optical Zoom Ex iew 22X ExView 22X Digital Zoom 264X 264X 276X 276X Total Z Zoom Speed Tele -Wide: 3.9 sec...
  • Page 65 Model Numbers SVFT-M22/SVFT-M22-C SVFT-M35/SVFT-M35C Camera Product Codes Specifications 8747-00/8747-01 9104-00/9104-01 rmats NTSC/PAL Type Color Day/Night Color Optical Zoom Digital Zoom Total Zoom 264X 420X Zoom Speed OPTICAL w ide/DIGITAL tele: 3.9 sec Tele-Wide: 4.6 sec Image Device 1/4-inch interline transfer CCD 1/4-inch interline transfer CCD 8(H) x 494 (V), 380,000 pix...
  • Page 66: Vicon Standard Equipment Warranty

    Software supplied either separately or in hardware is furnished on an “As Is” basis. Vicon does not warrant that uch software s hall be error (bug) free.
  • Page 67 Notes XX157-14-00 Rev 908 SVFT-M Maximum Security Camera Dome System14BVicon Standard Equipment Warranty • 59...
  • Page 68 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) 1489 566300 Fax: +44 (0) 1489 566322 Germany vin-videotronic infosystems gmbh...

Table of Contents