Vicon XX152-10-01 Installation & Operating Manual

Fixed camera dome

Advertisement

Quick Links

XX152-10-01
FIXED CAMERA DOME
Warning: To reduce a risk of fire or electric shock, do not expose
indoor units to rain or moisture.
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet
your requirements or that the operation will be entirely error free or perform precisely as
described in the documentation. This system has not been designed to be used in life-critical
situations and must not be used for this purpose.
Copyright © 2009 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
SurveyorVFT is a trademarks and ViconNet and Kollector are registered trademarks of Vicon Industries Inc.
ExView is a trademark of Sony Corporation.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44 (0) 1489-566300
WEB: www.vicon-cctv.com
Vicon part number 8009-8152-10-01
Rev 209 Section 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XX152-10-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vicon XX152-10-01

  • Page 1 Warning: To reduce a risk of fire or electric shock, do not expose indoor units to rain or moisture. Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation.
  • Page 3: Fcc Notice

    FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNING This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception.
  • Page 4: Important Safeguards

    20. Replacement Parts - Use only Vicon specified replacement parts or an approved equivalent to prevent unit damage and 6. Attachments - Use only UL Listed, Vicon recommended injury.
  • Page 5: Table Of Contents

    DIP Switch Settings............................13 Camera Synchronization ..........................13 Autoiris Adjustments ...........................13 Final Installation ............................15 Disassembly..............................27 Operation ...........................28 Maintenance ........................28 Care and Cleaning of Lower Dome......................28 Fuse Replacement............................28 Shipping Instructions .......................29 Reference...........................30 Technical Information .......................33 Contents • i XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 6: Quick Installation

    Quick Installation In-Ceiling - No Access to Ceiling ii • Quick Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 7 In-Ceiling – Access to Ceiling Quick Installation • iii XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 8 Pendant - Indoor iv • Quick Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 9 Pendant – Outdoor Quick Installation • v XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 11: Introduction

    Video Recorders and ViconNet Workstations via ViconNet software. The pre-installed LAN interface board allows direct plug-in to a system network hub, switch or router. The Vicon SurveyorVFT camera dome can be used in conjunction with competitive PTZ drivers through DIP switch selection. Audio input capability is available on the ViconNet version.
  • Page 12 “-V5” , “-F” or “-T” to the model number and a -75, -30 or -40 to the product code, respectively (ex., SVFT-C3312-V5, 8753-75; SVFT-C3312-V5-C, 8753-76, SVFT-C3312-F, 8753-30; SVFT-C3312-FC, 8753-31, SVFT-C3312-T, 8753-40; SVFT-C3312-TC, 8753-41). 2 • Introduction XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 13: Installation

    Installation Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier’s responsibility to deliver the equipment in the same condition as it left the factory. Inspection for Visible Damage Immediately inspect the cartons upon delivery. Make a note of any visible damage on all copies of the carrier’s freight bill.
  • Page 14: Surveyorvft Fixed Dome Components

    Sunshield A sunshield pre-installed over the housing used on the outdoor pendant version is for radiation sun-blocking protection. CAUTION: For any environment subject to moisture, use the outdoor pendant model. 4 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 15 Installation • 5 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 16: Mounting The Unit

    Be sure the area around the selected location is clear of obstacles (such as steel beams, headers, pipes, electrical wiring, etc.) that would interfere with mounting. Video, sync, and power cables must be routed to the location. 6 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 17: Mounting From Above The Ceiling

    (such as steel beams, headers, pipes, electrical wiring, etc.) that would interfere with mounting. Video, sync, and power cables must be routed to the location. Installation • 7 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 18: Optional Independent Support

    The ring should be firmly seated against the tile without warping the tile. Refer to Figure 3B. 6. Complete the installation as described in the previous procedure. When using this kit, the flippers squeeze the mounting ring assembly for a snug fit. 8 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 19: Indoor Pendant

    Installation of Optional In-Ceiling Mounting Kit Indoor Pendant The indoor pendant model mounts on a Vicon mount or a 1.5-in. vertical pipe with an appropriate coupling. The pipe is a standard 1.5-in. NPT type and must be oriented vertically so the SurveyorVFT fixed camera dome can effectively hang from the pipe.
  • Page 20 Add 1 in. (25 mm) of extra length to each cable for termination (if not previously terminated) and cut them. The approximate length of each cable should be 14 - 15 in. (356 - 381 mm). Continue with the section on Cable Connections. 10 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 21: Outdoor Pendant

    Outdoor Pendant The outdoor pendant model mounts on a Vicon mount or a 1.5-in. vertical pipe with an appropriate coupling. The outdoor version includes a sunshield, heater and weather protection. Be sure the area around the selected location is clear of obstacles (such as steel beams, headers, pipes, electrical wiring, etc.) that would interfere with mounting.
  • Page 22: Camera Power Connections

    ST connector. Camera Power Connections Note: Vicon systems and components, like most electronic equipment, require a clean, stable power source. Voltage irregularities such as surges, drops, and interruptions can affect the operation of your equipment and, in severe cases, damage certain components. Vicon strongly recommends the use of line conditioners, voltage regulators, and uninterruptible power supply (UPS) systems.
  • Page 23: Dip Switch Settings

    Figure 5. Use a small jeweler’s screwdriver to make adjustments. Turning the potentiometer opens and closes the iris to regulate light extremes. Turning the potentiometer clockwise opens the iris wider, allowing more light. Autoiris control is DIP switch selectable. Installation • 13 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 24 Figure 5 Potentiometer/DIP Switch Location Figure 6 DIP Switch Settings 14 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 25: Final Installation

    Note: When adjusting the focus, it is recommended that the iris be completely open (a dark condition, either at night or using a filter) so that the depth of field does not influence the adjustment. Figure 7 Camera/Lens Adjustments – 5-50 mm Version Shown Installation • 15 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 26 Press the lower dome into the SurveyorVFT and verify that it snaps into place on both sides. The upper edge of the lower dome should be flush with the ceiling plane. Refer to Figure Figure 9 In-Ceiling Mount Final Installation 16 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 27 Press the lower dome into the SurveyorVFT and verify that it snaps into place on both sides. Refer to Figure 10. Figure 10 Pendant Mount Dome Final Installation Installation • 17 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 28 Press the lower dome into the SurveyorVFT and verify that it snaps into place on both sides. Tighten the four (4) trim ring screws to hold the lower dome in place. Refer to Figure 10. 18 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 29 Although the ViconNet software does not limit the number of Groups and Users that can be created, the SurveyorVFT Camera Dome has Users and Groups limitations. For ViconNet version 5, the dome can support the first 20 Groups (including Administrators and Guests) and the first 100 Users. Installation • 19 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 30: Configuring The Network Settings

    PC that is running the VNSetup, a unique password must be entered. The screen will display how many units there are and how many of those 20 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 31 0-4, where 4 is most information. Note: The Apply button must be pressed for changes to take effect. Note: Verify all IP addressing parameters with your IT administrator. Installation • 21 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 32 The Install TAB allows the user to install/upgrade newer versions. Choose the correct version and click Install to send to the selected unit. Install Info Tab The Info TAB displays the selected IP product general information/ Info 22 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 33: Advanced Tab

    Default setting is 1500. This setting also allows the VOX mechanism to be deactivated, having audio ON all the time. VOX Off Threshold – Defines the audio level at which the input shuts OFF. Default setting is 1200. Installation • 23 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 34 VOX Off Threshold VOX Silence Period – Defines the time between reaching VOX OFF level and the actual audio turns off. Default setting is 5000 ms. Function list: VOX Silence Period 24 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 35: Viconnet Configuration

    Open the Network Setup and Site Name setup window. Network Settings window will display. See Figure below. Change the required parameters and click OK. (See your IT administrator for specific network parameters.) Application of the camera will restart. Installation • 25 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 36 Refer to the ViconNet workstation manual XX113 for complete information on operation. A copy of the manual can be found on the CD included. 26 • Installation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 37: Disassembly

    5. If it is necessary to completely remove the SurveyorVFT, remove all cable connections and disconnect the clip on the end of the safety cord from the tab on the enclosure. Installation • 27 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 38: Operation

    There is a fuse located in the SurveyorVFT. When necessary, replace it with a fuse of the same value, 0.5 A, 250 V, 5x20 mm slo blo for indoor version; the outdoor version has an additional 1.0 A, 250 V, 5x20 mm slo blo fuse. 28 • Operation XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 39: Shipping Instructions

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 40: Reference

    Caution: Careful selection of the proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended are installed. In all cases, coaxial cable impedance should be 75 ohms.
  • Page 41 Twisted-Pair Cable Caution: Careful selection of the proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended are installed. Materials Use a pure copper stranded or solid conductor with or without a tin plating to obtain a low DC resistance. Do not use cable with either steel or aluminum stranded conductor because these do not transfer signals effectively for long distances.
  • Page 42: Network Cable

    Network Cable Caution: Careful selection of proper cable is essential to obtain the best performance. Vicon assumes no responsibility for poor performance when cables other than the recommended types, or equivalent, are used. Materials Use pure copper stranded conductors to obtain a low DC resistance. The preferred insulation and cable jacket is Polyvinyl chloride (PVC).
  • Page 43: Technical Information

    ViconNet: RJ-45 connector for video and data. Audio: 1/8-in. phono jacks. Fuse: Indoor: 0.5 A, 250 V, 5x20 mm slo blo. Outdoor: 1.6 A, 250 V, 5x20 mm slo blo, additional. Technical Information • 33 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 44 Camera can be setup using remote recorder or workstation GUI. Permissions can be assigned for macro create & edit, alarm setup, Authentication, Reports and System Status. Supports up to 20 Groups and 100 Users. 34 • Technical Information XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 45 -40 to 150° F (-40 to 65° C). Storage Humidity: Up to 90% relative, noncondensing. Wind Load: Outdoor: heavy rain or snow driven by winds up to 80 mph. Technical Information • 35 XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 46 3.3-12 varifocal SVFT-W3312-C with autoiris 83.9° - 23.16° 61.9°- 17.93° SVFT-W550A/ 5-50 varifocal SVFT-W550A-C with autoiris 51.8°- 5.6° 39.2°- 4.3° SVFT-W550DN/ 5-50 varifocal SVFT-W550DN-C with autoiris 51.8°- 5.6° 39.2°- 4.3° 36 • Technical Information XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 47 Software supplied either separately or in hardware is furnished on an “As Is” basis. Vicon does not warrant that such software shall be error (bug) free. Software support via telephone, if provided at no cost, may be discontinued at any time without notice at Vicon’s sole discretion.
  • Page 48 38 • Vicon Standard Equipment Warranty XX152-10-01 Rev 209 SurveyorVFT Fixed Camera Dome...
  • Page 49 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) 1489 566300 Fax: +44 (0) 1489 566322 Germany vin-videotronic infosystems gmbh...

This manual is also suitable for:

Surveyorvft

Table of Contents