Vicon surveyor1000 Programming Manual

Camera dome system

Advertisement

Quick Links

XX100-10-01
Surveyor1000 Camera Dome System
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet
your requirements or that the operation will be entirely error free or perform precisely as
described in the documentation. This system has not been designed to be used in life-critical
situations and must not be used for this purpose.
Copyright © 2002 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Surveyor1000 and its logo are trademarks of Vicon Industries Inc.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300 INFOFAX: 800-287-1207 WEB: www.vicon-cctv.com
Vicon Part No. 8009-8100-10-01 Section 1 Rev 202

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the surveyor1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vicon surveyor1000

  • Page 1 XX100-10-01 Surveyor1000 Camera Dome System Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
  • Page 5: Table Of Contents

    Pan/Tilt Controller............................6 Camera Controller............................7 Alarm Handling ............................10 Relay Driver ..............................12 Source Titling ............................... 12 Preset/Tour Handler ............................ 14 Language ..............................15 Install Defaults ............................. 15 Contents • • • • i XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 6: Introduction

    Surveyor2000 Direct Control software, see Instruction Manual XX031-10. All functions programmed into the Surveyor1000 stay resident in the Dome Assembly and do not occupy any external CPU memory. In addition, the Surveyor1000 memory can be flash upgraded with the latest software by using the Flash Upgrade software kit, see Instruction Manual XX031-20.
  • Page 7 NOTES Introduction • • • • 3 XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 8: Software Features

    The Camera Dome will not move outside these limits. The only exceptions are prerecorded tours and previously stored presets. Preset 94 (Enter Dome Menu System) — Many Surveyor1000 features are accessed through a series of on-screen menus. These are described in the following programming menu sections and accessed by storing preset 94.
  • Page 9 Recalling preset 97 has no effect. Presets 98 and 99 (Programming Left and Right Autopan Limits) — When a Surveyor1000 is selected on a keyboard, pressing the AP (autopan) key will start the camera in motion, panning at a predetermined speed.
  • Page 10: Programming Menus

    Language, Idioma, Langue and Sprache, to alert an operator that this prompt is related to changing the language. When selected at the currently flashing word, the menus will display the new language. Install Defaults — Resets the Surveyor1000 to the factory default settings. All previously programmed titles and settings are lost when this function is accessed.
  • Page 11: Camera Controller

    Autoiris Adjust feature prevents an operator from adjusting the Autoiris level from the keypad, when disabled. NOTE: When the Surveyor1000 is in simplex mode, manual iris control is disabled. The Iris Open and Iris Close buttons will regulate the Average Iris Level as described above, but the option of manually controlling the iris level directly will not be available.
  • Page 12 This includes cameras in windowed rooms such as lobby areas, where intense sunlight coming through the window renders features on a silhouetted person unrecognizable. 8 • • • • Programming Menus XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 13 The White Balance allows the user to override the automatic color correction feature in the Surveyor1000. To adjust the red and blue gain, white balance mode must first be changed to Manual (default is automatic). In manual mode, select either the Red Gain or Blue Gain menu and adjust that parameter on the sliding scale.
  • Page 14: Alarm Handling

    Surveyor1000 to take a picture of the person. At the same time, a relay driver completes a circuit, which locks the inner door, preventing open egress.
  • Page 15 The final menu choice available on the Alarm Input Controller menu is to Program Alarm Titles. This function and sub-menu are also available from the Source Titling menu and will be reviewed in that section. Programming Menus • • • • 11 XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 16: Relay Driver

    When Source Titling is selected from the programming menu, we enter the Display Controller series of sub-menus. These control another powerful feature of the Surveyor1000, the ability to overlay numerous titles on top of the video image without the use of external devices.
  • Page 17 Not all cameras require the same information, and an essential feature in one location becomes a drawback in another. Programming Menus • • • • 13 XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 18: Preset/Tour Handler

    Preset/Tour Handler The Preset/Tour Handler function manages the 79 presets and 4 tours resident in the Surveyor1000. Tours are available on any keypad. The first sub-menu in the Preset/Tour Handler allows selecting options to Program Presets. Once the Preset Number is selected (1-79), these include: •...
  • Page 19: Language

    This feature is not available on earlier versions. Install Defaults Finally, the Install Defaults option restores all Surveyor1000 settings to their factory defaults. This affects all programmed functions. Programming Menus • • • • 15...
  • Page 20 16 • • • • Programming Menus XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 21 Programming Menus • • • • 17 XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 22 18 • • • • Programming Menus XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 23 Programming Menus • • • • 19 XX100-10-01 Rev 202 Surveyor1000 Camera Dome Programming...
  • Page 25 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Infofax: 800-287-1207 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom 44/(0) 1489/566300 Fax: 44/(0) 1489/566322 Brussels Office Planet II - Unit E...

This manual is also suitable for:

Surveyor 2000

Table of Contents