Oscillator 3 - Access Virus Rack XL User Manual

Table of Contents

Advertisement

the Virus. Modulations such as these may also
be implemented via the Modulation Matrix (see
the section "ASSIGN" below).
01111111111111111112
1 OSCILLATOR2
FltEnv~Fm
61111111111111111154
í

OSCILLATOR 3

MODE
The VIRUS offers a third master oscillator per
voice that you can activate whenever you need
it. It lets you come up with even more complex
sounds by adding more oscillations and spectra
to the signal. When Oscillator 3 is switched on,
(i.e. OSCILLATOR 3 mode is not set to the OFF
position), the polyphony of the VIRUS decreas-
es by up to six voices, depending on how many
voices use the third oscillator in MULTI mode.
01111111111111111112
1 OSCILLATOR 3
Mode
61111111111111111154
The second position of OSCILLATOR 3 mode is
called SLAVE. Here Oscillator 3 is active, but –
just like when it is set to the OFF position – no
further parameters are available and visible. In
this operating mode, Oscillator 3 is the "twin" of
Oscillator 2. It adds further oscillations, thus
making the sound fatter and more animated.
Oscillator 2 and 3 are handled collectively using
Oscillator 2's control features just as if the two
were a single oscillator. All settings that you dial
in for Oscillator 2 apply to Oscillator 3, with one
exception – DETUNE. This parameter runs
counter to that of Oscillator 2.
You can select the waveshapes individually for
+0≤
Oscillator 3 via the following OSCILLATOR 3
mode options: sawtooth, square (pulse width
modulation), sine, triangle and all further spec-
tral waveshapes. You have three further param-
eters available once you set Oscillator 3 to an
individual waveshape. These are explained fur-
ther below. All other parameters as well as the
settings for the oscillator modulations (LFO
pulse width modulation and so forth) are dictat-
ed by Oscillator 2. This doesn't limit the func-
tionality of the third oscillator by much (if at all),
but it certainly facilitates intuitive handling. The
FM, Sync and Ring Modulator functions are not
available for the third oscillator.
Like all other oscillators, the level of Oscillator 3
is controlled via OSCVOL.
VOLUME
The individual volume level of oscillator 3. Addi-
tionally the level is controlled by OSC VOL. (Not
available if OSCILLATOR 3 MODE = "OFF" or
"SLAVE".)
Off≤
01111111111111111112
1 OSCILLATOR 3
Volume
61111111111111111154
PDF VERSION - RESTRICTIONS APPLY
ACCESS VIRUS RACK XL OS5
Oscillator 3
64≤
63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents