3
General Installation Guidelines
Switch Chassis
The switch is designed to be installed in a standard 19-inch equipment rack.
Before continuing with switch installation, first review the general guidelines and
switch cooling requirements in this chapter.
This chapter includes these sections:
◆
"General Installation Guidelines" on page 24
◆
"How to Install the Switch in a Rack" on page 25
◆
"Optional Expansion Module" on page 30
◆
"How to Install an Optional Expansion Module" on page 30
Be sure to follow the guidelines below when choosing a location.
◆
The installation location should:
be able to maintain its temperature within 0 to 50 ° C (32 to 122 ° F) and its
■
humidity within 10% to 90%, non-condensing.
provide adequate space (approximately five centimeters or two inches) on
■
all sides for proper air flow.
be accessible for installing, cabling and maintaining the device.
■
allow the status LEDs to be clearly visible.
■
◆
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference, such as
radios and transmitters.
◆
Make sure that the unit is connected to a separate grounded power outlet and
is powered from an independent circuit breaker. As with any equipment, using
a filter or surge suppressor is recommended. Verify that the external power
requirements for the switch can be met as listed under
page
32.
– 24 –
"Power Supply Units" on