(2) Get operation of reader (GETO: GET Operation)
This command allows the Reader/Writer to read the current operation conditions. Even after setting
operation command (SETO) is executed, the old information shall be read out unless the reboot is
completed.
Command
Response
*(S) Space Character
Example 1) When executed command is read at startup,
[Tx] GETO iec<LF>
[Rx] GETO0000 iec=" rdid -ant 122322 -tmo 100"<LF>
Example 2) When Input 1 function setting is read,
[Tx] GETO in1<LF>
[Rx] GETO0000 in1=1 0 "rdid -ant 122322 -tmo 100"<LF>
Example 3) When Output 1 function setting is read,
[Tx] GETO ot1<LF>
[Rx] GETO0000 ot2="31 0 mbk 1 dpt 2 dat=XXXX0000"<LF>
V750 RFID READER/WRITER, ANTENNA
OPERATION MANUAL
GETO (S) param1 (S) ... param n<LF>
Specifies a single setting item. (not required '-' before the item)
* Multiple setting items cannot not be specified.
GETO (S) param1=value1 (S)<LF>
74 of 110
2006-06, REV.C
©OMRON CORPORATION 2006