(1) Set Operation of Reader (SETO: ST Operation)
This command is to write operation conditions into the nonvolatile memories in the Reader/Writer. The
new setting shall be enabled at the upcoming startup.
Command
Response
*(S) Space Character
Example 1) When the receiver of response after command execution is set RS-232,
[Tx] SETO cli=2<LF>
[Rx] SETO0000<LF>
Example 2) When the executed command at the start up is set as [rdid -ant 122322 -tmo 100] ,
[Tx] SETO iec="rdid -ant 122322 -tmo 100"<LF>
[Rx] SETO0000<LF>
Example 3) When Input 1 function setting is set as [Command execution, start up edge," rdid -
ant 122322 -tmo 100" ] ,
[Tx] SETO in1=1 0 "rdid -ant 122322 -tmo 100"<LF>
[Rx] SETO0000<LF>
Example 4) When output 2 function setting is set [output time;500ms when ERR],
[Tx] SETO ot2=01 500
[Rx] SETO0000<LF>
Example 5)
When output 2 function setting is set as; if data read from memory bank1 and
address 2 is XXXX0000 after data read completes normally, output status shall be kept until
upcoming evaluation, 出力 3 機能設定を、正常読取り完了時、メモリバンク 1 、アドレス 2 から読
み出したデータが XXXX0000 のときに次回の判定まで出力状態を保持する場合
[Tx] SETO ot3=31 0 1 2 dat=XXXX0000
[Rx] SETO0000<LF>
V750 RFID READER/WRITER, ANTENNA
OPERATION MANUAL
SETO (S) param1=value1<LF>
Putting equal between a single setting item and a setting value specifies the
value (no need to put '-' before setting item).
* Multiple setting items can not be applicable.
SETO0000<LF>