3.1.5.3 Reader/Writer operation conditions
Specifying following option in the operation setting command (SETO) or operation read command
(GETO) enables to set or read the Reader's operation conditions.
Reader Network Settings (GETR/SETR)
Code
Content
CLI
Receiver of response
after command
execution.
IEC
Initial Executed
Command. Executed
command at startup.
IN1
Input port #1 function
setting
IN2
Input port #2 function
setting
IN3
Input port #3 function
setting
IN4
Input port #4 function
setting
OT1
Output port #1 function
setting
OT2
Output port #2 function
setting
V750 RFID READER/WRITER, ANTENNA
OPERATION MANUAL
User setting value
0:None
1:Ethernet
2:RS-232C
Executed command sequence(実行されるコ
マンド)
Example
RDID –seq SOC –tmo 500
Function
0:None
1:Command execution
Timing
0:Startup
Command
Example
1 0 "RDID –seq SOC –tmo 500"
Same as IN1
Same as IN1
Same as IN1
Timing
00:None
11:RUN output
12:ERR output
20:COM output
2n:ATn: Current antenna(s) (n=1~4)
31:NML (evaluated normal completion)
32:ERR (evaluated completion with error
occurring)
Output time
10∼2550 (ms)
0:Status kept until upcoming evaluation.
-Output time is effective only for NML/ ERR
setting
Evaluation condition
* Refer to the following list.
Same as OT1
71 of 110
Factory Settings
1:Ethernet
(None)
(None)
(None)
(None)
(None)
(None)
ng
(None)
2006-06, REV.C