Lock code
Option shall be specified with values following the code that indicates option type.
Option Details
Code
Item
-seq
Communication
sequence
-ant
Antenna number
-tmo
Timeout
V750 RFID READER/WRITER, ANTENNA
OPERATION MANUAL
shall be specified in 32-bit hexadecimal format as below. (0x not required)
・Format: XXXXXXXX ... XXXXXXXX
X: 0 to 9 , A to F
When Lock command is executed, this code shall be specified depending on
the type of lock.
For GEN2 system, 10-digit Lock value shall be specified with 0, 1, * (0 and 1
mean Action and * means MASK) for following five areas; Kill pwd, Access
pwd, EPC memory, TID memory, and User memory.
・Format: XXXXXXXXXX
X: 0 or 1 or *
(0:Off , 1:On , *:do-nothing)
chr.
1
2
Kill pwd
Action
pwd
perma
Fields
read/
lock
write
Specifies the communication sequence according to
the operating conditions. For "Read ID" command, all
parameters can be specified. For other commands,
only SOC can be specified.
・ SOC: Single Once
・ SRP: Single Repeat
・ MOC: Multi Once
・ MRP: Multi Repeat
Can specify the order of antenna to operate from first
to 9thwith figure of 1, 2, 3, and 4. The figure 1 to 4
means antenna's identical number. If an antenna is
specified multiply, the antenna executes sequence
multiply depend on the order.
・ Format: X ... XXXXXXXXX (Max 9 characters)
X: 1 to 4
Specifies time parameter for communication process
with 0 to 2550 in decimal number. The numbers after
rounding down to the 10 is added ms as a specified
value (the least significant digit is always "0"). If the
communication sequence is SOC/MOC, the specified
value is the communication time. If the value is
specified 0 (zero), communication process will
continue until STOP command is executed. If the
communication sequence is SRP/MRP, the specified
value is maximum time between response (0 can't be
specified for SRP/MOC/MRP).
・ 0, 10...2550 (ms)
※32bit 単位との内容を追記!!
3
4
5
Access pwd
EPC memory
pwd
perma
pwd
perma
read/
lock
write
lock
write
Specified Value
58 of 110
6
7
8
9
TID memory
User memory
pwd
perma
pwd
write
lock
write
Default Value
-seq SOC
-ant 1
-tmo 250
©OMRON CORPORATION 2006
10
perma
lock
2006-06, REV.C