2.3.3 Session Setting

Following table shows 4 flags as a session flag for communication command. S0 is set as factory default
setting for Once command, and S2 is set for Repeat command.
Communication option
Once
・Single Once
・Multi Once
Repeat
・Single Repeat
・Multi Repeat
(Reference)Function/ effect of each Session flag
Flag
Tag persistence time after tag energizing is stopped
S0
None
S1
500ms to 5s (Same when tag is energized)
S2/S3
2s or more
SL
2s or more
V750 RFID READER/WRITER, ANTENNA
OPERATION MANUAL
Flag
S0
Factory default setting.
In this setting, the reader communicates with all tags existing
in the read field whenever a command is executed.
S1/S2/S3
In this setting, the reader communicates with un-read tags (it
ignores once-read tags.)
If S1 is set, tag refreshes its S1 flag when a specified time has
passed after flag setting (after communication transaction)
regardless of whether tag energized or not. It means that the
tags are read repeatedly in a certain interval.
If S2 or S3 is set, tag refreshes its S2 or S3 flag when a
specified time has passed after tag energizing stopped. It
means that the tag is not re-read unless the tag stays out of
the read field for the specified time.
S2
Factory default setting.
In this setting, the reader communicates with new-detected
tags existing in the read field during the command execution.
S0
When there is a tag the reader can not read because of flag
conflict with other readers, this setting enables the reader to
read the tag.
S1/S3
If another reader set in the near process line uses S2 flag, the
reader same flag may encounter the flag conflict. S1 and S3
flags are used to avoid this conflict.
Setting S3 provides same operation as S2 setting.
If S1 is set, tag refreshes its S1 flag when a specified time has
passed after flag setting (after communication transaction)
regardless of whether tag energized or not. It means that the
tags are read repeatedly in a certain interval.