OPERATION MANUAL
Specifies one or more following items as additional
information of tag communication results that are
output in the response. Specified item(s) shall be
returned according to the specified order with
commas.
・ ANT: An antenna number which reads the tag first.
・ CNT: The count of tag read.
・ EPC: EPC code only.
・ PEP: PC bit and EPC code
・ PER: PC bit, EPC code, and CRC
For ID read, EPC/PRP/PER determines the EPC data
type to be returned. For ID write or Data write, if
EPC/PEP/PER is specified, EPC data before
rewriting shall be returned. (If EPC data length is 0, it
will be "*".)
Specifies the password data with 32-bit 8 digit
numbers in hexadecimal format for access of ID Write
command, Data Write command, and Lock
command, and Kill password for Kill command. (0x
not required)
XXXXXXXX
For ID Write, Data Write, or Lock, if this option is
omitted or specified "00000000", Access password
shall not be used .(If Access password of the Tag is
0x00000000, the tag can be processed. For Kill
command, the Access password shall not be
0x00000000. If so, 7Ferror occurs.)
Specifies the number(s) that indicates the protocol
type. Multiple numbers can be specified.
・ 2: Class1 Generation2
59 of 110
-tif EPC
-pwd 00000000
-ptc 2
2006-06, REV.C