Channel 1
Haze
output
Level
Channel 2
Fan output
level (fan
will always
run if haze
is active)
Channel 3
Special
functions
Note that when the heaters are on, Channel 3 can stay at level 0 without
affecting the operation of the machine.
This means that Channel 3 need only go to 100% once at the start of a show,
then it can assume a default of zero without the heaters turning off, thus ensuring
that the machine is ready when the show runs again. To turn the heaters off, use
the Heater Off macro.
18
DMX value
Function
range
0-19
Idle range
20-29
Haze 5%
30-39
Haze 10%
........
.......
210 -255
Haze 100%
DMX value
Function
range
0-19
Idle range
20-29
Fan 5%
30-39
Fan 10%
........
.......
210 -255
Fan 100%
DMX value
Function
range
0-50
Idle range
51-100
Prime
101-150
Auto Fan
mode
151-200
Heater off &
shutdown
201-255
Heater on
(normal
operation)
DMX control
Macro description
None
Macro description
None
Macro description
None
5 seconds within
range to activate
once
None (level
triggered)
5 seconds within
range to activate
once
None, but heaters
will stay on if
channel 3 returns to
zero
Default
value
0
Default
value
0
Default
value
0