HEIDENHAIN iTNC 530 HSCI Service Manual page 428

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

Functional test by
means of DriveDiag
February 2012
DANGER
Ask the machine manufacturer and observe the machine manufacturers's safety precautions
(set-up mode, etc.)!
Switch on the machine.
Turn the feed-rate potentiometer to a small value.
Call DriveDiag. --> See "DriveDiag" on page 9 – 91.
Open the following page:
Start a probing cycle with the TT.
Check the lamp at TT touch probe ready (X13).
When the touch probe is ready, the lamp shines green.
Deflect the tool touch probe by hand.
Check the lamp at trigger signal of TT touch probe (X13).
When the touch probe is deflected, the lamp shines green.
The message Stylus deflected appears in the machine display.
26 – 429