The columns in the ERR window have the following meanings:
Column in ERR window Description
Number
Class
Group
Error message
The individual error messages can be selected with the cursor; the open Help window shows the
associated text.

4.4 CE key

Acknowledge displayed error messages by pressing the CE key.
If the error cause is still existing, the error message will be displayed again. --> Correct the error!
4 – 26
Error number defined by HEIDENHAIN or the machine manufacturer
(-1: No error number defined)
Error class; defines the reaction of the control:
ERROR
Group error
The error reaction depends on the status or current operating mode
of the control.
FEED HOLD
The feed-rate enable is deleted.
PGM HOLD
The program run is interrupted (the control-in-operation symbol blinks)
PGM ABORT
The program run is interrupted (INTERNAL STOP.)
EMERG. STOP
An emergency stop is triggered.
RESET
The iTNC executes a system restart.
WARNING
Warning message, program run resumes
INFO
Information message, program run resumes
Error source; shows the cause of the error:
GENERAL
General error
OPERATING
Error during machining and machine traverse
PROGRAMMING
Error in programming and editing
PLC
PLC error message of the machine manufacturer
Displayed error text
Clear error message (Clear Error)
Note
Messages reporting particularly severe errors cannot be confirmed with the CE key.
The control must be restarted.--> Press the END key.
If this does not work --> Switch off the power switch of the machine and wait for several seconds
before switching it on again.