15.3 Procedure

15 – 216
Enter the code number to call the machine parameter list.
Press the MOD key.
Press the UPDATE DATA soft key.
Press the SELECT SOFT KEY. --> All NC software versions and service packs on the control now
appear in the selection window..
The currently used software version and possibly the corresponding service pack are distinguished
by an asterisk in the Sel column.
Place the cursor on the marked NC software version.
Note
NC software versions do not have the extension SP (e.g., 606420.001).
Service packs are distinguished by SP. The name of a service pack includes the NC software
version so that it can be assigned uniquely (e.g. 606420.001 SP1).
Load the software in the correct order:
First load the NC software, then the associated service pack!
Exception:
There are "full versions" that contain the NC software including service pack. In this case an
NC software without SP version is NOT displayed in the selection window. Load the full version!
DANGER
You may only reactivate the NC software currently used by the machine!
A change to another NC software version is not described in this Service Manual and may only
be made in agreement with the machine manufacturer.
Press the SELECT soft key.
Confirm your selection with the YES soft key.