Specifying The Condition For The Trigger Out Jack To Function; Specifying The Output Level Of The Electronic Signal Transmitted With Each Input; Switching The Output Level For Electronic Signal Transmission Manually; Specifying The Zone With Which The Trigger Out Jack Functions Are Synchronized - Yamaha Aventage RX-A780 Owner's Manual

Hide thumbs Also See for Aventage RX-A780:
Table of Contents

Advertisement

Specifying the condition for the TRIGGER OUT jack to
function
Specifies the condition for the TRIGGER OUT jack to function.
Setup menu
"System" > "Trigger Output" > "Trigger Mode"
Settings
The TRIGGER OUT jack functions in sync with the power status of the
Power
zone specified with "Target Zone."
The TRIGGER OUT jack functions in sync with the input switching in the
zone specified with "Target Zone."
Source
An electronic signal is transmitted according to the setting made in
"Source."
Select this to manually switch the output level for electronic signal
Manual
transmission with "Manual."
Note
For details on "Target Zone" in the "Setup" menu, see the following:
▪ "Specifying the zone with which the TRIGGER OUT jack functions are synchronized" (p.145)
Specifying the output level of the electronic signal
transmitted with each input
Specifies the output level of the electronic signal transmitted with each input, switching
when "Trigger Mode" is set to "Source".
Setup menu
"System" > "Trigger Output" > "Trigger Mode" > "Source"
Choices
HDMI 1-5, AV 1-2, AUX, AUDIO 1-5, TUNER, PHONO, (network sources), Bluetooth,
USB, AirPlay, MusicCast Link, SERVER, NET RADIO
Settings
Stops the electronic signal transmission when you switch to the input
Low
source specified in this option.
Transmits the electronic signal when you switch to the input source
High
specified in this option.
Switching the output level for electronic signal
transmission manually
Switches the output level for electronic signal transmission manually when "Trigger
Mode" is set to "Manual". This setting can also be used to confirm proper function of
the external device connected via the TRIGGER OUT jack.
Setup menu
"System" > "Trigger Output" > "Trigger Mode" > "Manual"
Settings
Low
Stops the electronic signal transmission.
High
Transmits the electronic signal.
Specifying the zone with which the TRIGGER OUT
jack functions are synchronized
Specifies the zone with which the TRIGGER OUT jack functions are synchronized.
Setup menu
"System" > "Trigger Output" > "Target Zone"
Settings
When "Trigger Mode" is set to "Power," electronic signal transmission is
synchronized with the power status of the main zone.
Main
When "Trigger Mode" is set to "Source," electronic signal transmission is
synchronized with the input switching in the main zone.
When "Trigger Mode" is set to "Power," electronic signal transmission is
synchronized with the power status of Zone2.
Zone2
When "Trigger Mode" is set to "Source," electronic signal transmission is
synchronized with the input switching in Zone2.
When "Trigger Mode" is set to "Power," electronic signal transmission is
synchronized with the power status of the main zone or Zone2.
All
When "Trigger Mode" is set to "Source," electronic signal transmission is
synchronized with the input switching in the main zone or Zone2.
Note
For details on "Trigger Mode" in the "Setup" menu, see the following:
▪ "Specifying the condition for the TRIGGER OUT jack to function" (p.145)