Fisher FIELDVUE DVC6200 Instruction Manual page 4

Digital valve controller
Hide thumbs Also See for FIELDVUE DVC6200:
Table of Contents

Advertisement

Hot Key
1 Instrument Mode
2 Control Mode
3 Protection
4 Stabilize/Optimize
Configure / Setup
1
1 Basic Setup
2 Detailed Setup
3 Calibrate
Online
1 Configure / Setup
2 Device Diagnostics
3 Device Variables
HART Application
1 Offline
2 Online
3 Utility
1
4 HART Diagnostics
Notes:
1-1-1 indicates fast-key sequence to reach menu
1
This menu is available by pressing the left
arrow key from the previous menu.
2
Instrument level AD, PD, and ODV only.
3
Instrument level ODV only.
4
Instrument level HC, AD, and PD only.
5
Instrument level HC only.
6
Fast key sequence for Alert Record with instrument level ODV is 1-2-3-7.
1
DVC6200 Digital Valve Controller
Field Communicator Menu Tree for
Instrument Level HC, AD, PD, and ODV
Basic Setup
1-1
1 Setup Wizard
2 Performance Tuner
2 Stabilize/Optimize
Detailed Setup
1 Mode and Protection
2 Response Control
3 Alerts
1-2
4 Status
5 Instrument
6 Valve & Actuator
7 SIS/Partial Stroke
Partial Stroke
1-2-7
1 PST Enable
2 PST Vars View/Edit
3
Calibrate
1-3
1 Travel Calibration
2 Sensor Calibration
3 Relay Adjust
4 Restore Factory
4
Settings
Device Diagnostics
2
1 Alert Conditions
2 Status
3 Device Record
4 Stroke Valve
3
5 Partial Stroke Test
Device Variables
1 Analog In
3
2 Tvl Set Pt
3 Travel
4 Drive Signal
5 Pressures
6 Variables
7 Device Information
8 DD Information
3-5
2
3
Mode and Protection
1 Instrument Mode
1-2-1
2 Control Mode
3 Restart Ctrl Mode
4 Burst Mode
2
5 Protection
5
Response Control
1 Tuning
1-2-2
2 Tvl/Press Control
3 Input Char
4 Define Cust Char
5 Dynamic Response
3
Valve & Actuator
1 Manufacturer
1-2-6
2 Valve Serial Num
3 Valve Style
4 Actuator Style
5 Tvl Sensor Motion
6 View/ Edit Feedback
Connection
Travel Calibration
1-3-1
1 Auto Tvl Calib
2 Man Tvl Calib
Sensor Calibration
1-3-2
1 Press Sensors
2 Analog In Calib
Device Record
2-3
1 Temp Max
2 Temp Min
3 Run Time
4 Num of Power Ups
Pressures
1 Pressure A
Variables
2 Pressure B
1 Aux Input
3 Pressure Diff
2 Temperature
4 Supply Press
2
3 Temp Max
3-6
4 Temp Min
Device Information
5 Cycle Count
1 HART Tag
6 Tvl Accum
2 Device ID
7 Raw Tvl Input
3 Manufacturer
8 Run Time
4 Model
9 Num of Power Ups
3-7
5 Device Rev
6 Firmware Rev
7 Hardware Rev
8 Inst Level
9 HART Univ Rev
4
Burst Mode
1-2-1-4
1 Burst Enable
2 Burst Command
3 Cmd 3(Trending)Press
Tuning
1-2-2-1
1 Travel Tuning
2 Integral Settings
3 Pressure Tuning
Tvl/Press Control
1 Tvl/Press Select
1-2-2-2
2 Tvl/Press Cutoffs
3 Travel Limits
4 Pressure Control
5 End Pt Press Control
Dynamic Response
1-2-2-5
1 SP Rate Open
2 SP Rate Close
3 Lag Time
3 Lead/Lag
Alerts
1 Electronics Alerts
2 Sensor Alerts
1-2-3
3 Environment Alerts
4 Travel Alerts
5 Travel History Alerts
6 SIS Alerts
6 Alert Record
Status
1 Instrument Time
1-2-4
2 Calibration and Diagnostics
3 Operational
4 Integrator
Instrument
1-2-5-1
1 General
1-2-5
2 Units
3 Analog Input Range
4 Relay Type
5 Zero Pwr Cond
6 Max Supply Press
7 Aux Term Mode
8 Inst Date and Time
9 Calib Status and Loc
Units
1-2-5-2
1 Pressure Units
2 Temp Units
3 Analog In Units
Analog Input Range
1-2-5-3
1 Input Range Hi
2 Input Range Lo
Calib Status and Loc
1-2-5-9
1 Last Calib Status
2 Calib Loc
5
3
4
3
3
6
General
1 HART Tag
2 Message
3 Descriptor
4 Date
5 Valve Serial Num
6 Inst Serial Num
7 Polling Address
6
iii
iii

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents