DVC6200 Digital Valve Controller
Function/Variable
Partial Stroke Test Variables
(3)
View/Edit
(2)
Performance Tuner
Polling Address
Pressure A
Pressure B
Pressure Control Active Enable
Pressure Deviation Alert Enable
Pressure Deviation Alert Point
(3)
Pressure Deviation Time
Pressure Differential
Pressure Integral Control Enable
Pressure Integral Gain
Pressure MLFB Gain
Pressure Proportional Gain
Pressure Range Hi
Pressure Range Lo
(3)
Pressure Sat Time
(2)
Pressure Sensor Shutdown
Pressure Sensors—Calibration
(3)
Pressure Set Point
Pressure Tuning Set
Pressure Units
Protection
Raw Travel Input
Reference Voltage Shutdown
Relay Adjust
Relay Type
Restart Control Mode
Restore Factory Settings
Run Time
Set Point Rate Close
Set Point Rate Open
Setup Wizard
Stabilize/Optimize
Status
Stroke Valve
(2)
Supply Pressure
Supply Pressure Lo Alert Enable
Supply Pressure Lo Alert Point
Temperature
Temperature Maximum
NOTE: Italicized Fast-Key Sequence indicates fast-key sequence is applicable only for instrument level ODV.
1. Coordinates are to help locate the item on the Field Communicator Menu Tree for Instrument Level HC, AD, PD, and ODV.
2. Instrument level AD, PD, and ODV only.
3. Instrument level ODV only.
4. Instrument level HC, AD, and PD only.
5. Instrument level HC onl
y.
ii
ii
Fast-Key
Coordinates
Sequence
1-2-7-2
3-D
1-1-2
2-B
1-2-2-1-1-5
8-A
1-2-5-1-7
6-F
3-5-1
4-G
3-5-2
4-G
1-2-4-3-1
8-H
(3)
1-2-3-6-2
8-F
(3)
1-2-3-6-3
8-F
1-2-3-6-4
8-F
3-5-3
4-G
1-2-2-1-3-2
8-B
1-2-2-1-3-3
8-B
1-2-2-1-3-1-3
10-B
1-2-2-1-3-1-2
10-B
1-2-2-2-4-1
9-C
1-2-2-2-4-2
9-C
1-2-2-2-5-4
8-C
1-2-3-2-3
9-D
1-3-2-1
4-E
1-2-2-2-5-3
8-C
1-2-2-1-3-1-1
10-B
1-2-5-2-1
6-G
Hot Key-3
1-A
1-2-1-5
4-B
3-6-7
5-H
1-2-3-1-3-7
12-C
1-3-3
2-E
1-2-5-4
5-F
1-2-1-3
4-B
1-3-4
2-E
2-3-3
4-F
3-6-8
5-H
1-2-2-5-2
6-C
1-2-2-5-1
6-C
1-1-1
2-B
Hot Key-4
1-A
(5)
1-1-2
2-B
1-2-2-1-1-4
8-A
2-2
2-E
2-4
2-F
3-5-4
4-G
1-2-3-3-1-2
10-C
1-2-3-3-1-1
10-C
1-2-3-3-1-3
10-C
3-6-2
5-G
3-6-3
5-G
2-3-1
4-F
(1)
Function/Variable
Temperature Minimum
Temperature Sensor Shutdown
Temperature Units
Travel
Travel / Pressure Cutoff Hi
Travel / Pressure Cutoff Lo
Travel / Pressure Select
Travel Accumulator
Travel Accumulator Alert Enable
Travel Accumulator Alert Point
Travel Alert Dead Band
Travel Alert Hi Enable
Travel Alert Hi Hi Enable
Travel Alert Hi Hi Point
Travel Alert Hi Point
Travel Alert Lo Enable
Travel Alert Lo Lo Enable
Travel Alert Lo Lo Point
Travel Alert Lo Point
Travel Deviation Alert Enable
Travel Deviation Alert Point
Travel Deviation Time
Travel Integral Control Enable
Travel Integral Gain
Travel Limit / Cutoff Hi Alert Enable
Travel Limit / Cutoff Lo Alert Enable
Travel Limit Hi
Travel Limit Lo
Travel MLFB Gain
Travel Proportional Gain
Travel Sensor Motion
Travel Sensor Shutdown
Travel Set Point
Travel Tuning Set
Travel Velocity Gain
Valve Group Enable
Valve Serial Number
Valve Style
Zero Power Condition
Fast-Key
(1)
Coordinates
Sequence
2-3-2
4-F
3-6-4
5-H
1-2-3-2-2
9-D
1-2-5-2-2
6-G
3-3
2-F
1-2-3-4-1
10-E
1-2-3-4-7-3
12-F
1-2-2-2-2-1
9-B
1-2-3-4-7-4
12-F
1-2-2-2-2-2
9-B
1-2-2-2-1
6-B
3-6-6
5-H
1-2-3-5-3-2
10-F
1-2-3-5-3-1
10-F
1-2-3-5-3-3
10-F
1-2-3-4-3
10-E
1-2-3-4-6-1
12-E
1-2-3-4-5-1
12-D
1-2-3-4-5-3
12-D
1-2-3-4-6-3
12-E
1-2-3-4-6-2
12-E
1-2-3-4-5-2
12-D
1-2-3-4-5-4
12-D
1-2-3-4-6-4
12-E
1-2-3-4-4-1
12-D
1-2-3-4-4-2
12-D
1-2-3-4-4-3
12-D
1-2-2-1-1-2
8-A
1-2-2-1-1-3
8-A
1-2-3-4-7-1
12-E
1-2-3-4-7-2
12-E
1-2-3-4-7-5
12-F
1-2-2-2-3-1
8-B
1-2-3-4-7-6
12-F
1-2-2-2-3-2
8-B
1-2-2-1-1-1-4
10-A
1-2-2-1-1-1-2
10-A
1-2-6-5
4-D
1-2-3-2-1
9-D
1-2-3-4-2
10-E
3-2
2-F
1-2-2-1-1-1-1
10-A
1-2-2-1-1-1-3
10-A
1-2-3-6-5-2
10-G
1-2-3-7-5-2
1-2-5-1-5
6-F
1-2-6-2
4-D
1-2-6-3
4-D
1-2-5-5
5-F