Power and Data Cabling Requirements
Power
The Bad Boy™ Spot Luminaire requires standard AC power distribution from 200-240 VAC, 50/60
Hz, 15A maximum. The upper enclosure provides a Neutrik® connector for power input. Use the
provided AC Line Cord Cable Assembly (25.9812.0902.5) to connect power.
Refer to
"AC Line Current / Power vs. Voltage"
various voltages.
Data
DMX512 Cables
The Bad Boy Luminaire is equipped with two, 5-pin XLR connectors for DMX IN and DMX THRU
(out) applications. DMX IN requires a 5-pin, female XLR connector and DMX THRU requires a 5-
pin, male XLR connector. When purchasing or constructing data cables, it is important that not only
the correct cable type be used, but also quality cable to ensure a reliable DMX512 system. Your
cabling should meet the following USITT DMX specification requirements:
•
Suitable for use with EIA485 (RS485) operation at 250k baud.
•
Characteristic impedance 85-150 ohms, nominally 120 ohms.
•
Low capacitance.
•
Two twisted pairs.
•
Foil and braid shielded.
•
24 AWG minimum gauge for runs up to 1000 feet (300m).
•
22 AWG minimum gauge for runs up to 1640 feet (500m).
Note: Microphone type cables and other general purpose, two-core audio or signal cables are not
suitable for use with DMX512.
1 0
U
M
SER
ANUAL
LAMP
INFO
125
01:34
hrs
34C
temp
TEST
THRU
1400w
COMM
CONFIG
COMM
043
DMX
addr
A
univ
STATUS
OK
Figure 2-1: Power Input Connector
ACTIVE ON LY
WHE N FIXTURE
IS POW ERED
AC IN
200 -240 VAC
DMX
ETHERNET
50 / 60 Hz
IN
15A Max
on page 83 for details on power consumption at
Neutrik® AC
Power Connector
02.9812.0001C