Figure 3: Pulse Mode Home Screen
# of Pulses
Figure 4: Pulse Adjust
FIELD
Pulse Count
Volume
Units
Pulse Width
Refer to the manufacturer's documentation for information regarding the external device
providing the pulse input. In general, larger numbers result in better output resolution.
Some devices are capable of operating in varying frequency and pulse widths. The
minimum recommended pulse width is 4 mS (milliseconds). Set the pulse width to a
value less than the minimum pulse width of the external device. Press Save
the entered values, then press Exit
ALLOWABLE VALUES
1 - 10000
0.1 - 10000
fl. oz. – GAL or mL – L (dependent on units setting)
4 mS – 60 mS
to return to the pulse mode home screen, or
8
OPERATION
Flow Rate
Pulse Volume / Units
Pulse Width
to retain