45° Corner Installation 4''/7; 45° Or Less Corner Installation 4''/7 - Montigo H34DF Installation & Maintenance Manual

H34 series indoor gas fireplace
Table of Contents

Advertisement

45° Corner Installation 4''/7''
Attach an EEL-45 (45° elbow) directly onto the flue collar. Cut the MXT-
20 to suit, and attach it to the EEL-45. Slide the fireplace into position
and attach to the termination.
Figure 10. Corner Installation
NOTICE
Corner Installation is available for NATURAL GAS UNITS ONLY
16
45° or less Corner Installation 4''/7''
Use an MTO-4 termination and an MFL-1 or MFL-2 (12" or 24" compressed
length) and a frame, if appropriate. Flex may be turned to obtain desired
degree of angle required but must not exceed 45°.
Termination
RHS 100
Heat Sheild
MXT-20
EEL- 45 Elbow
Flue Collar
NOTE: Through the wall venting kits are also available for both the
Straight and the Corner Installation. The Kit includes a heat shield, a
MFL-12 (f/f) flexible pipe, and a termination with or without a mounting
frame.
Installation
Termination
RHS 100
Heat Sheild
Flex Section
Flue Collar
Figure 10.b Corner Installation Flex
XG0146 - 180405