45° Corner Installation 5''/8; 45° Corner Installation 5''/10; 45° Or Less Corner Installation 5''/8; 45° Or Less Corner Installation 5''/10 - Montigo Phenom PL38 Installation & Maintenance Manual

Hide thumbs Also See for Phenom PL38:
Table of Contents

Advertisement

45° Corner Installation 5''/8'':
Attach a PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT-20
to suit, and attach it to the PEL-45. Slide the fireplace into position and
attach to the termination.
45° Corner Installation 5''/10'':
Attach a REL-45 (45° elbow) directly onto the flue collar. Cut the RXT-20
to suit, and attach it to the REL-45. Slide the fireplace into position and
attach to the termination.
Figure 14. Corner Installation
NOTICE
Corner Installation is available for TOP VENT UNITS ONLY. Ensure
minimum Vertical Venting Height is maintained in corner installations:
48'' for P*42
56'' for P*52
XG0199 - 170223
PTO-4F Termination
(RTO-4F for 5''/10'')
104
RHS 101 (RHS 104 for 5''/10'')
Heat Sheild
RXT 20
PXT 18 (RXT 20 for 5''/10'')
PEL- 45 Elbow
REL - 45 Elbow
(REL 20 for 5''/10'')
PEL- 90 Elbow
REL - 90 Elbow
(REL 90 for 5''/10'')
PEXT - 1
REXT - 1
(REXT - 1 for 5''/10'')
Flue Collar
Flue Collar
40" for P*38
45° or less Corner Installation 5''/8'':
Use a PTO-4 termination and a PFL-1 or PFL-2 (12" or 24" compressed
length) and a frame, if appropriate. Flex may be turned to obtain desired
degree of angle required but must not exceed 45°.
45° or less Corner Installation 5''/10'':
Use a RTO-4 termination and a RFL-4 (48" compressed length) and a
frame, if appropriate. Flex may be turned to obtain desired degree of
angle required but must not exceed 45°.
RTO-4F
NOTE: P*38DF, P*42DF: The PFVK01 / PFVK01F kit is available for
top vent corner FLEX application (NG only). The kit includes a heat
shield, a PFL-18 (f/f) flexible pipe, and a termination with or without a
mounting frame.
NOTE: P*52DF: The PFVK01F kit is available for top vent corner FLEX
application (NG only). The kit includes a heat shield, a RFL-2 (f/f) flexible
pipe, and a termination with or without a mounting frame.
Installation
PTO-4F Termination
(RTO-4F for 5''/10'')
RHS 101 (RHS 104 for 5''/10'')
Heat Sheild
Figure 14.b Corner Installation Flex
RTO-4F
104
PFL4 Flex Section
(RFL4 for 5''/10'')
RFL4
Flue Collar
23