Montigo H34DF Installation & Maintenance Manual

Indoor residential gas fireplace
Table of Contents

Advertisement

Installation & Maintenance Manual
XW2002
XW2004
XG0146
DANGER
Read and understand this manual.
Improper installation, adjustment,
alteration, service or maintenance
can cause serious injury, property
damage
or
even
assistance or additional information
consult a qualified installer, service
agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are
extremely hot while the fireplace is
on and remain hot even after the
fireplace has been turned off. Safety
screens are available and can reduce
the risks of severe burns. Please
keep children away from the fireplace
at all times.
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
death.
For
XW2006
XW2012
XW2014
H34DF HC34DF
HL34DF HR34DF
Indoor
Residential
Gas Fireplace
WARNING
Do not store or use gasoline or any
other flammable vapors and liquids in
the vicinity of this or any other gas
burning appliance. A fire or explosion
my occur causing serious injury,
property damage or even death.
NOTICE
Installer: Leave this manual with the
appliance. Do not remove.
Consumer: Retain this manual for
maintenance and future reference. Do
not Discard.
NOTICE
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
supplier's instructions.
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
If you cannot reach your gas supplier,
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
call the fire department.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
050211.1

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H34DF

  • Page 1 Danger of harming radiation Environment your hands Irritant Slippery floor Watch your step Cutting High temperatures Glass hazard Danger of suffocation XW2014 XG0146 050211.1 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    ▪ Roof mounted Terminations Section 8: Installing the Accessories ..........22 - 26 Standard Top Vent (no elbows or offsets) ........9 ▪ Installing the H34DF* Log Set ...........22 Top Vent (two elbows one offset) ..........9 ▪ Installing the HC34DF* Log Set ..........23 Top Vent (multi-elbows and offsets) ...........9...
  • Page 3: Introduction

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    Should it be impossible to meet the venting requirements laid „ BEFORE YOU START: out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    H*34DF Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Installation Checklist on Page 4 for general information Safety, as well as efficiency of operation, should be considered when on preparing for a successful installation of your fireplace. selecting the fireplace location.
  • Page 6: Section 2: Framing The Fireplace

    43” 43” to corners only to corners only 2” min. 2” min. Exterior Exterior Wall Wall H34DF*, HL34DF* & HR34DF* HC34DF* ONLY, see figures 7 and 25a. Q” M” Q” N” N” P” P” Figure 4. Combustible Framing for shelves over the fireplace, Top vent.
  • Page 7: Clearances

    A clearance maintains a 6" clearance. to combustibles of 9" for H34DF*& HR34DF* and a clearance to combustibles of 11" for HC34DF* , & HL34DF* is required to the underside of any combustible shelf materials, Figure 3.
  • Page 8: Section 3: The Direct Vent System

    Should it be impossible to ensure that the termination is the highest point or to Flue Cover Plate meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options. Flue Gasket nOTES FOR PLannInG VEnTInG: 7”...
  • Page 9: Section 3-2: Installing A Roof Mounted Termination

    H*34DF Indoor Gas Fireplace Installation Section 3-2: InSTaLLInG a ROOF MOUnTED DIRECT VEnT TERMInaTIOn (MVTK-1) MVTK1 PVTK1 Termination This section applies to installations where the direct vent termination Termination 2’ min. will be roof mounted. Section 3-2-1: VEnTInG LaYOUT: Roof Mounted Termination Support ring Selection of components and details of venting lay out should Support plate...
  • Page 10: Standard Roof Vent (One Elbows No Offsets)

    H*34DF Indoor Gas Fireplace Installation MVTK1 Termination MEXT Sections Support plate 32’ max Support ring 18” Max. Figure 11c. Rear vent, Roof mounted venting (1 = 90° bend). Page 10 XG0146 - 050211.1...
  • Page 11: Section 3-3: Installing A Wall Mounted Termination

    H*34DF Indoor Gas Fireplace Installation Section 3-3: InSTaLLInG a waLL MOUnTED DIRECT VEnT 4). Installation of termination from inside structure TERMInaTIOn A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction. This section applies to installations where the direct vent termination will be wall mounted.
  • Page 12: Section 3-3-1: Venting Layout

    15 with an 'X'. If the 'X' falls on or above the top boundary of the shaded Shaded area) please contact a local area, the installation is acceptable. Montigo dealer for Power Venting Options. WARNING: An inspection of the explosion relief flappers and door 39”...
  • Page 13: Rear Vent, Wall Mounted Graph, H*34Df

    8' MIN Flex Section at MAX If your installation does not fall within the venting graph parameters, (non-Shaded horizontal area) please contact a local Montigo Exterior dealer for Power Venting options. Wall Hearth Horizontal Run (in.) Figure 15b. Top Vented, wall mounted Multi-elbow installation. See Figure 16.
  • Page 14: Rear Vent, Wall Mounted Termination (45° Corner)

    H*34DF Indoor Gas Fireplace Installation 45° Corner Installation. Attach an EEL-45 (45° elbow) directly onto the flue collar. Cut the MXT-20 to suit, and attach it to the EEL-45. Slide the fireplace into position and attach to the termination. RHS 100 MXT-20 EEL-45 Figure 17.
  • Page 15: Section 3-3-2: Venting Components

    MXT - 20 (20" f/f Section) possible hot spots. MEXT - 1 (12" f/m Section) Montigo recommends the use of a flex section for the final pipe „ MEXT - 2 (24" f/m Section) connected directly to the fireplace offering greater flexibility of MEXT - 3 (36"...
  • Page 16: Section 3-3-3: Heat Shields

    H*34DF Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a wall Mounted RHS100 Heat shield. nstalling a wall Mounted RHS7 Heat shield The RHS100 Heat shield MUST be used where the RHS7 Termination The RHS7 Heat shield CannOT be used wITHIn 36" horizontal or (Figure 18 and 18a) CannOT be used.
  • Page 17: Section 4: Wiring

    H*34DF Indoor Gas Fireplace Installation Section 4: wiring Models H34DFnI HL34DFnI H34DFLI HL34DFLI ON / OFF HC34DFnI HR34DFnI Green (CPI / IPI MODE Orange Not Used) HC34DFLI IPI/CPI ON/OFF Battery Holder 4 x 1.5V AA Type Black 880 Valve VALVE BATTERY Chassis 120 Vac INPUT...
  • Page 18: Installing Remote On/Off Wall Switch

    H*34DF Indoor Gas Fireplace Installation Installing the remote On/Off wall Switch The H*34DF* gas valve may be connected to a wall switch. Do nOT connect any external power to the remote switch. The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace, depending on the model of the unit.
  • Page 19: Section 5: Installing The Gas Line

    1/8” N.PT. plug to be fitted with a hose barb. follow the appropriate local codes or your area. DO NOT connect Montigo requires a service shut off valve be located in an „ the fireplace to pressures in excess of 1/2lb. This will damage the accessible location to isolate the gas supply.
  • Page 20: Section 6: Finishing

    Combustible mantels and mouldings may be safely installed over the are for fire hazard prevention to combustible materials. top and on the front of the H34DF*, HL34DF* & HR34DF* fireplaces provided that they do not project beyond shaded area shown in Figure New technology, to meet consumer and government demands for the 25.
  • Page 21: Section 7: Installing And Removing The Door

    H*34DF Indoor Gas Fireplace Installation Section 7: Installing & Removing the Door Removing the door: The H*34DF* doors are removed in a few simple steps. Follow these Step 5: instructions below to remove the Horizontal access panel, unlatch the Ensure the tool is firmly door buckles and, remove the door.
  • Page 22: Section 8: Installing The Accessories

    Installing the Logs: log, as shown in figure 28c. Install the glass door. If the flame The H34DF* fireplace is supplied with five ceramic fibre logs. Unpack does not appear satisfactory, double-check the air inlet and the logs and handle them very carefully.
  • Page 23: Installing The Hc34Df* Log Set

    H*34DF Indoor Gas Fireplace Installation Installing the HC34DF* Log Set Step 5. Place the left two logs, and the centre log shown below in (Previous model figure 29d. HD34DF*) Installing the Logs: The HC34DF* is supplied with a seven piece ceramic fibre logset. Unpack the logs and handle them very carefully.
  • Page 24: Installing The Hl34Df* Firestones

    These may be spaced at random or in a visual pattern of your Figure 31a. Ensure ONLY one layer of firestones cover the preference in the burner tray. See the Montigo web site for photographs burner and no firestones cover the pilot.
  • Page 25: Installing The Hr34Df* Designer River Rocks

    H*34DF Indoor Gas Fireplace Installation Installing the Designer River Rocks: The HR34DF* is supplied with (40) forty faux ceramic fibre river rocks. 2 in1 Faux Rock "B" Unpack the rocks and handle them very carefully. Shown Below: 2 in1 Faux Rock "C" Top View Top View Figure 32c.
  • Page 26 H*34DF Indoor Gas Fireplace Installation Figure 32j. Completed lower layer of ceramic Rock. Step 8. Install the first faux ceramic "E" Rocks on top of the lower level Figure 32p. Place the sixth Top faux Rock on top, behind the pilot burner faux of rocks.
  • Page 27: Section 9: Operation

    H*34DF Indoor Gas Fireplace Operation Section 9: Start up Sequence Standing (Continuous) Pilot Ignition (SIT NOVA 820) with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 28: Start-Up Sequence Sit Proflame Gas Valve

    H*34DF Indoor Gas Fireplace Operation Proflame SIT Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 29: Start-Up Sequence With Honeywell Electronic Ignition

    H*34DF Indoor Gas Fireplace Operation Honeywell Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 30: Maintenance

    H*34DF Indoor Gas Fireplace Maintenance Lighting Instructions See pages 27 to 29. Hi-Lo Burner adjustment: (SIT nova 820). General The H*34DF* is equipped with an adjustable burner, allowing you to Have the fireplace and installation inspected yearly. The raise or lower the flames. To adjust the flames, locate the black knob „...
  • Page 31: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. all service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 31...
  • Page 32: Spare Parts List

    RBT1148 nG Orifice (Rear) RBT1150 LP Orifice (Rear) all service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 32 XG0146 - 050211.1...
  • Page 33: Appendix

    H*34DF Indoor Gas Fireplace Appendix appendix a: Venting Terminations Location Canada* USA** 12 inches 12 inches clearance to the termination frame above grade, veranda, porch, deck, or balcony clearance to top of doors or operable windows 12 inches 12 inches clearance to sides or bottom of door or operable windows 9 inches 12 inches...
  • Page 34: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 35: State Of Massachusetts

    H*34DF Indoor Gas Fireplace Appendix appendix C: State of Massachusetts amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to nFPa-54, Chapter 10 (1) Revise nFPa-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 36 H34DF Residential Gas Fireplace Ferndale, washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0146 - 050211.1...

This manual is also suitable for:

Hc34dfHl34dfHr34df

Table of Contents