Warning:
Improper installation, adjustment,
alteration, service or maintenance can
cause injury or property damage. Refer to
this manual. For assistance or additional
information consult a qualified installer,
service agency or the gas supplier.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.

For Your Safety:

Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity
of this or any other
appliance.
Installation
Operation &
Maintenance
H-Series BF
Gas Fireplace
H34BF
H38BF
H42BF
Safety Notice:
Glass doors on gas fireplaces are
extremely hot while the fireplaces is on
and remain hot even after the fireplace
has been turned off. Safety screens
are available and can reduce the risks
of severe burns. Please keep children
away from the fireplace at all times.
Check local codes and
read all instructions prior to
installation.
Leave this manual with the
owner.
C
®
US

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H34BF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo H34BF

  • Page 1: For Your Safety

    Installation Operation & Maintenance H-Series BF Gas Fireplace H34BF H38BF H42BF Safety Notice: Glass doors on gas fireplaces are extremely hot while the fireplaces is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns.
  • Page 2: Table Of Contents

    Installing and Framing the Fireplace ......3 embers. This fireplace is available in two models. Installing the Gasline ............4 The H34BF is rated for Natural Gas at 18,000 BTU/H (5.28 Kilowatts) The Remote Switch ............4 Input or Propane at 18,000 BTU/H (5.28 Kilowatts) Input.
  • Page 3: Installation

    WARNING: 0" clearance 0" clearance to corners only to corners only H34BF 33 When this appliance is installed directly on carpeting, tile or H38BF 37 any combustible material other than wood flooring, it must be H42BF installed on a metal or wood panel extending the full width and Clearances depth of the appliance.
  • Page 4: Installing The Gasline

    H-Series BF Gas Fireplace Installation Installing The Gas Line Vent Installation The H-Series BF is certified for use with standard 4" B-Vent and requires The gas line must be installed before finishing the H-Series BF Fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. no B-Vent appliance connector.
  • Page 5: The Remote Switch

    H-Series BF Gas Fireplace Installation Installing The Remote Switch Mantels & Surrounds NOTE: National Canadian Gas Association mantel test requirements The H-Series BF's gas valve, located behind the lower trim, may be are for fire hazard prevention to combustible materials. connected to a wall switch.
  • Page 6: Wiring

    H-Series BF Gas Fireplace Installation Wiring Gas Control and Pilot Wiring H-Series BF-I Honeywell (Q3450) Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Gas Control Junction Box Cover Connector Fuse Junction Box Fan Plug Receptacle Black 115VAC White 24VAC Green Grnd Screw...
  • Page 7: Removing And Installing The Door

    H-Series BF Gas Fireplace Installation Removing and Installing Wiring for the optional Fan Kit All H-Series BF fireplaces may be equipped with optional fan kits for the Door circulating heat into the living space. Removing the door: Installations in Canada which employ the fans must be electrically The door is held in place by a lip on the top of the metal frame and two grounded in accordance with CSA C22.1 Canadian Electrical Code buckles at the bottom.
  • Page 8: Installing The Logset

    H-Series BF Gas Fireplace Installation H34BF Installing the Log Set Place the bottom left and right logs as shown below in figure Installing the Logs: Log 'D' 14d. The H-Series BF is supplied with four ceramic fibre logs and a ceramic Place the top left and right logs as shown in figure 14e.
  • Page 9 H-Series BF Gas Fireplace Installation H38BF H42BF Installing the Log Set Installing the Logs: The H-Series BF is supplied with three ceramic fibre logs and a ceramic fibre logset base. Unpack the logs and handle them very carefully. Air Inlet Ports Bottom Log Top Right Log Top Left Log...
  • Page 10: Lighting Instructions

    H-Series BF Gas Fireplace Operation - Model H-Series BF H-Series BF with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 11 H-Series BF Gas Fireplace Operation - Model H-Series BF-I H-Series BF-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 12 H-Series BF Gas Fireplace Operation - Model B-Series BF-A B-Series BF-A with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 13: Operation

    H-Series BF Gas Fireplace Operation Maintenance Lighting Instructions General Have the fireplace and installation inspected yearly. The inspection See pages 19 and 20. ■ must include, but is not limited to, the following: Burner Adjustment • A visual check of the entire vent system and termination. The H-Series BF is equipped with an adjustable burner, allowing you •...
  • Page 14: Gas Control Valve

    H-Series BF Gas Fireplace Maintenance Gas Control Valve Troubleshooting H-Series BF-I Power HONEYWELL SV 9500 /SV9600 Generator Pilot Adjustment Screw Troubleshooting Sequence NOTE: Wall Switch Before Troubleshooting, Familiarize Yourself With The Startup And Checkout Procedure. START INSET C H EC K: ·...
  • Page 15: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 16 H-Series BF Gas Fireplace Maintenance Notes Spare Parts - H-Series BF H34BF H38BF H42BF NG Gas Valve SIT RGC1006 RGC1006 RGC1006 LP Gas Valve SIT RGC1005 RGC1005 RGC1005 NG & LP Gas Valve AF RGC3016 RGC3016 RGC3016 NG Gas Valve HIS...
  • Page 17 H-Series BF Gas Fireplace Notes Notes Page 17 Part No. XG0145...
  • Page 18 XG0150 Canadian Heating Products Inc. Montigo Del Ray Corp. Langley, BC V4W 4A1 Ferndale, WA 98248...