45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT-
20 to suit, and attach it to the PEL-45. Slide the fireplace into position
and attach to the termination.
Figure 15. Corner installation.
XG0181 -112811.1
Installation
45° or less Corner Installation.
Use an PTO-4 termination and an PFL-1 or PFL-2/PFL-2 (12" or
24" compressed length) and a frame, if appropriate. Flex may be
turned to obtain desired degree of angle required but must not
exceed 45°.
PXT-18
PEL-45 Elbow
PEL-90 Elbow
Figure 15a. Flex installation. (NG Models Only)
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation. The Kit includes a heat
shield, a PFL-12 (f/f) flexible pipe, and a termination with or without
a mounting frame.
L42DF* Indoor Gas Fireplace
Page 15