Montigo DIVINE H34DFN Installation & Maintenance Manual
Montigo DIVINE H34DFN Installation & Maintenance Manual

Montigo DIVINE H34DFN Installation & Maintenance Manual

Divine single sided indoor direct vent gas fireplace
Table of Contents

Advertisement

Quick Links

WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— WHAT TO DO IF YOU SMELL GAS
phone. Follow the gas supplier's instructions.
department.
DANGER
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
must be installed for the protection of children and
other at-risk individuals.
Installation & Maintenance Manual
®
C
US
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
DIVINE
Single Sided
INDOOR DIRECT VENT GAS FIREPLACE
H34DFN NG Traditional
H34DFL Propane Traditional
H34DFNI NG Traditional
H34DFLI Propane Traditional
HLB34DFNI NG Linear
HLB34DFLI Propane Linear
HLB34DFNI-2 NG Linear
HLB34DFLI-2 Propane Linear
H38DFN NG Traditional
H38DFL Propane Traditional
H38DFNI NG Traditional
H38DFLI Propane Traditional
HL38DFN NG Linear
NOTICE
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for suture reference.
CAUTION
DANGER
Read and understand this manual. Improper installation, adjustment,
alteration, service or maintenance can cause serious injury, property
damage or even death. For assistance or additional information
WARNING
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
HL38DFL Propane Linear
HL38DFNI NG Linear
HL38DFLI Propane Linear
HW38DFNI-2
HW38DFLI-2
H42DFN NG Traditional
H42DFL Propane Traditional
H42DFNI NG Traditional
H42DFLI Propane Traditional
HL42DFNI NG Linear
HL42DFLI Propane Linear
HW42DFNI-2
XG0228 - 021419

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIVINE H34DFN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo DIVINE H34DFN

  • Page 1 Installation & Maintenance Manual DIVINE Single Sided INDOOR DIRECT VENT GAS FIREPLACE H34DFN NG Traditional HL38DFL Propane Linear H34DFL Propane Traditional HL38DFNI NG Linear H34DFNI NG Traditional HL38DFLI Propane Linear H34DFLI Propane Traditional HW38DFNI-2 HLB34DFNI NG Linear HW38DFLI-2 HLB34DFLI Propane Linear H42DFN NG Traditional HLB34DFNI-2 NG Linear H42DFL Propane Traditional...
  • Page 2: Safety Alert Key

    Introduction Congratulations on your purchase of a Montigo Fireplace. H34DFN 18,000 With over 30 years of experience, Montigo is committed to providing H34DFNI 18,000 you with a gas fireplace that is not only a beautiful addition to your H34DFL...
  • Page 3: Table Of Contents

    General Contents Safety Alert Key ....................2 Section 5-3: GAS CONNECTION ......................28 H34 Gas line access ..........................28 Introduction ....................... 2 H38 Gas line access ..........................28 Section A: Before You Begin ........................4 H42 Gas line access ..........................28 Installation Checklist ..........................4 Section 6: Finishing ..................29 Standard Installation Checklist ......................5 Mantels &...
  • Page 4: Section A: Before You Begin

    Should it be impossible to meet the venting requirements laid out in NOTICE Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight Do not use this appliance if any part has been under water.
  • Page 5: Standard Installation Checklist

    General Standard Installation Checklist This standard installation checklist is to be used by the installer in conjunction with, not instead of, the instructions contained within this installation manual. Customer Date Installed: Install Address: Location of Fireplace: Installer: Model (circle one): H34DFNI, HLB34DFNI, HLB34DFNI-2, H38DFN, Dealer Phone: H38DFL, H38DFNI, H38DFLI, HL38DFN HL38DFL, HL38DFNI, HL38DFLI,...
  • Page 6 General LB1223-V5.2 SIT IPI -with screen AUG 17, 2015 LBL1205-V6.1 Stand. Pilot- Screen DEC06.2014 LBL1205-V6.0 Stand. Pilot- Screen NOV 24.2014 XG0228 - 021419...
  • Page 7: Section 1: Product Dimensions

    General Section 1: Product Dimensions Please review the Installation Checklist for general information on preparing for a successful installation of proper clearances to air conditioning ducts, electrical wiring Direct Vent installation. XG0228 - 021419...
  • Page 8: H38 Dimentions

    General XG0228 - 021419...
  • Page 9: Section 2: Framing

    Installation Section 2: Framing In Wall and Corner Dimensions WALL 1). Frame in the enclosure for the unit with framing materials. 2" MIN. 9" NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed 0"...
  • Page 10: Clearances

    Installation Clearances Installing the Nailing Flange Extension guidelines must be adhered to: For Rear Vent applications, the minimum clearance is 1" from the rear of materials. For Top Vent applications, the minimum clearance is 1" from the rear Nailing Flange Extension must be fasten securely into place, with nails the underside of any combustible shelf materials.
  • Page 11: Section 3: Venting

    Installation Section 3: Venting Montigo supplies a variety of direct venting and termination options. The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be selected such that it provides the shortest vent run possible. Should it be impossible...
  • Page 12: Section 3-2: Installing A Roof Mounted Direct Vent Termination

    Installation Section 3-2: Installing a Roof Mounted Direct Vent Termination Roof mounted terminations This section applies to installations where the direct vent termination will be roof mounted. terminations. See below. Section 3-2-1: Venting Layout PVTK1 PVTK1 Selection of components and details of venting lay out should adhere Termination Termination 2' min...
  • Page 13: Section 3-3-1: Venting Layout: Wall Mounted Termination

    Installation Section 3-3-1: Venting Layout: Wall Mounted Termination within non-shaded area. If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable. Selection of components and details of venting layout should adhere 72" to the following guidelines: Vent terminations must not be recessed in walls or siding.
  • Page 14: H34 Rear Venting Graph

    Installation 18'' Max. horozontal PXT Extention run with no vertical lift Heat Sheild If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable. Termination 18'' 26'' Max. If the vertical dimension from the hearth is 60" and the horizontal Hearth acceptable installation.
  • Page 15: H38 Top Venting Graph

    Installation Max. Heat Shield as per graph Termination If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable. 45'' Selection of components and details of venting layout should adhere Min. to the following guidelines: Vent terminations must not be recessed in walls or siding.
  • Page 16: H42 Top Venting Graph

    Installation Heat Shield 42"Max. Termination If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable. 49'' Selection of components and details of venting layout should adhere Min. to the following guidelines: Exterior Vent terminations must not be recessed in walls or siding.
  • Page 17: H38 Rear Venting Graph

    Installation 18'' Max. horozontal PXT Extention run with no vertical lift Heat Sheild Termination If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable. 18'' Max. Max. Selection of components and details of venting layout should adhere to the following guidelines: Hearth Vent terminations must not be recessed in walls or siding.
  • Page 18: H42 Rear Venting Graph

    Installation 18'' Max. horozontal PXT Extention run with no vertical lift Heat Sheild Termination If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable. 18'' 33'' Max. Max. Selection of components and details of venting layout should adhere to the following guidelines: Hearth Vent terminations must not be recessed in walls or siding.
  • Page 19: H34 - 45° Corner Installation 4''/7

    Installation Use an MTO-4 termination and an MFL-18 and a frame, if appropriate. Flex may be turned to obtain desired degree of angle required but and attach to the termination. Termination Termination Heat Sheild Heat Sheild Flex Section Flue Collar Flue Collar NOTICE NOTICE...
  • Page 20: 45° Corner Installation 5''/8

    Installation length) and a frame, if appropriate. Flex may be turned to obtain desired and attach to the termination. Termination Termination Heat Sheild Min. Vent center for Heat Sheild H42 - 49" Min. Vent Flex Section center for H38 - 45" Flue Collar Flue Collar NOTICE...
  • Page 21: Section 3-3: Installing A Wall Mounted Termination

    NOTE: If subject to a highly corrosive environment A Termination with a MOSR Frame is installed from the inside of the i.e. Seaside, Montigo recommends using Stainless Steel Termination. structure. These are commonly used in high-rise construction.
  • Page 22: Section 3-3-2.2: Alternate Venting Components 4"/7

    Installation The following venting components are approved for use with Montigo products. Please contact your local Montigo dealer for further information. Component Termination MTO4 (3" Length) 46DVA-HC MTO4F (3" Length) 46DVA-VCH MTO4FSS Frame Kits (Stucco Frame) MOSR (Stucco Frame) BSR-4 (4"...
  • Page 23: Section 3-3-2.2: Alternate Venting Components 5"/8

    Installation Component Simpson Duravent MetalFab Selkirk Flexmaster Montigo Part Number Part Number Part Number Part Number Part Number Part Number Termination PTO4 (3" Length) PTO4F (3" Length) Rigid Sections 58DVA-06 (6") 5DL6 (6") 5D6 (6") 5DT-06 58DVA-09 (9") 5DL9 (9") 5DT-09 58DVA-12 (12")
  • Page 24: Section 3-3-3: Heat Shields

    Installation Section 3-3-3: Heat Shields Installing the included heat shield Installing a Wall Mounted Heat shield The included Heat shield CANNOT be used WITHIN 36" horizontal or The RHS10* Heat shield must be used if vent pipe passes through a wall or ceiling within 6' of the unit.
  • Page 25: Sit Nova 820 Wiring

    Installation BATTERY BATTERY PACK PACK 1.5V AA type 1.5V AA TYPE 1.5V AA type 1.5V AA TYPE SPARK SPARK GREEN GREEN 1.5V AA TYPE 1.5V AA type MAIN WHITE WHITE MAIN Power BLACK 1.5V AA TYPE BLACK Power 1.5V AA type BLACK 120vac 60 hz BLACK...
  • Page 26 Installation OPTIONAL BATTERY PACK BATTERY PACK 1.5V AA TYPE 1.5V AA type 1.5V AA TYPE 1.5V AA type SPARK SPARK GREEN GREEN 1.5V AA TYPE 1.5V AA type WHITE WHITE BLACK 1.5V AA TYPE 1.5V AA type BLACK BLACK BLACK MAIN Power SENSOR SENSOR...
  • Page 27: Why Use Cpi Mode

    Installation POD - Pilot on Demand What is POD and CPI mode? 1). Access the control box. ignition system (IPI) which also includes a continuous pilot ignition (CPI) mode with an integrated seven day timer. In IPI mode, the pilot will light before the main burner, when the appliance is turned on using a wall switch, remote or from a thermostat.
  • Page 28: Section 5: Installing The Gas Line

    DANGER (Natural Gas or Propane shown by "N" or "L" in your model number If gas type is not compatible, contact your local Montigo representative. After gas line is connected, each appliance connection, valve and valve train MUST be checked while under normal operating pressure...
  • Page 29: Section 6: Finishing

    Installation Section 6: Finishing Combustible mantels and mouldings may be safely installed over the Combustible construction beyond shaded area shown allowed in shaded area Combustible facing material Fireplace Facing Combustible header remember the following: THE OPENING MUST NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply for the control compartments STEEL CONSTRUCTION ALLOWED WITHIN GREY and heat exchanger it also prevents access for servicing controls.
  • Page 30: Finishing Around The Fireplace

    Installation Finishing around the fireplace NOTE: National Canadian Gas Association mantel test requirements Please be aware, temperatures over the mantel will rise above normal Side wall clearances are 3". Combustible surrounds may be installed Combustible facing Non-combustible facing (allowed over face) Combustible header 6"*...
  • Page 31: Removing The Screen

    Installation Replacement Screens For replacement part order numbers, please refer to section and pull towards yourself. When the upper Screen Studs are free, lift "Replacement Parts" the screen at an angle from the lower slots from which the Screen Bottom Tabs are held. Place the screen in a safe place. NOTICE To Install Screens Screen Bottom Tabs at the lower corners of the screen.
  • Page 32: Removing The Door

    Installation The doors are removed in a few simple steps. Follow these below to remove the horizontal access panel, unlatch the door buckles and, in the lower end of the remove the door. Replace in reverse order. slot, (as shown), Then pull toward you.
  • Page 33: Section 9: Installing The Accessories

    Figure 21.c WARNING: This appliance is intended for use only with the included Montigo burners and accessories. Never install or add any additional or alternative media, rock wool or other material in this appliance. The use of additional or alternative materials may pose potential safety hazards, damage to the appliance, and void manufacturer’s warranty.
  • Page 34: Traditional Logset Installation H34Df

    Installation STEP 5: Place the top right log as shown. A notch is provided on the front right log, and a impression in the Rear bottom log. TOP RIGHT AIR INLETS PILOT BASE Figure 22. Figure 22.e STEP 1: Remove the glass door as described in the previous instruction.
  • Page 35: River Rock Kit H34Df

    Installation STEP 5: Remove the glass door as described in the previous instruction. STEP 1: Remove existing media and burner tray. TOP VIEW TOP VIEW SIDE VIEW SIDE VIEW 3 in 1 faux Rock "A" 1-pc 2 in1 Faux Rock "B & C" 2-pcs Figure 23.
  • Page 36 Installation Install Front (3) three of the supplied (5) five faux ceramic "D" Rocks as shown. Note cut surfaces of Rocks. ROCK "D" ROCK "D" ROCK "D" Figure 23.g Figure 23.m STEP 12: Install the first faux ceramic "E" Rocks on top of the lower level of rocks.
  • Page 37 Installation Figure 23.r Figure 23.s Figure 23.t Figure 23.u Figure 23.v XG0228 - 021419...
  • Page 38: Traditional Logset Installation H38Df

    Installation STEP 1: Remove the glass door as described in the previous STEP 1: Remove the glass door as described in the previous instruction. Place the bottom Rear log (Log A) instruction. Place the bottom Rear log Log A PILOT AIR INLETS Pilot Assembly Air Inlets...
  • Page 39: Wildfire Logset Installation Hw38Df

    Installation STEP 1: Remove the glass door as described in the previous STEP 1: Insert the rear log. Locate the retaining bracket and slide instruction. Place the bottom left and right logs as shown bracket behind Rear Log retaining plate and fasten bracket to log LEFT LOG RIGHT LOG BASE...
  • Page 40: H38 Designer River Rocks Installation

    Installation STEP 1: Install the new Rock Tray and front cover. Make sure the STEP 1: Install the new Rock Tray and front cover. Make sure the tray is not sitting on top of the pilot. tray is not sitting on top of the pilot. ROCK TRAY ROCK TRAY FRONT COVER...
  • Page 41: Section 10: Start Up Sequence

    Operation Section 10: Start up Sequence with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. WARNING/ CAUTION: Hot while in operation. Do not touch. Severe burns may result.
  • Page 42: Sit Proflame 2 Electronic Ignition

    Operation SIT Proflame 2 Electronic Ignition with American Flame Electronic Ignition STOP! Read the safety information above on this label. Remove the lower Horizontal access panel. minute audible clicking, thirty seconds of silence, and then another one minute of audible clicking). If the system locks out due to inadequate gas panel (if available).
  • Page 43: Remote Operation

    Operation Remote Operation The Proflame 2 System consists of the following elements: 1. Pilot Assembly Blue back lit LCD display 2. Proflame Gas Valve. 3. Proflame 2 Control Module 4. Wiring Harness Thermostat key 5. Variable Speed fans (If applicable) Mode key 8.
  • Page 44: Initializing The System For The First Time

    Operation Initializing the System for the first time Turn Off the Fireplace 1. Set master override switch to off position. With the system On, press 2. Install four (4) AA batteries into the battery holder. 3. Install three (3) AAA batteries in the back of the remote Remote Control.
  • Page 45: Room Thermostat (Remote Control Operation)

    Operation Room Thermostat (Remote Control Operation) Some jurisdictions and bedroom installations require the The Remote Control can operate as a room thermostat. The thermostat to be disabled. thermostat can be set to a desired temperature to control the comfort level in a room. To activate the function, press 1.
  • Page 46: Section 10: Cleaning And Maintenance

    Operation Section 10: Cleaning and Maintenance General must include, but is not limited to, the following: of the gas control valve A visual check of the entire vent system and termination, where accessible. lower control compartment) counter-clockwise. gaskets to ensure a proper seal. POWER Power HI-LO ADJUSTMENT...
  • Page 47: Troubleshooting Sit 820

    Check wiring diagram Main burner 1. Check wiring will not light 2. Check wall switch for proper connection Montigo dealer. Technician. Spare parts and accesories are available from your local Montigo dealer. XG0228 - 021419...
  • Page 48: Replacement Parts

    RLGSH38E RLGSHW38 RLGSH42 RLGSHW42 NG Gas Valve RGC1006 Propane Gas Valve RGC1005 NG Pilot RPA020 Propane Pilot RPA021 NG Burner Contact Local Montigo Dealer Propane Burner Thermocouple RTC182 Thermopile RPG001 Piezo Ignitor PIEZO Pilot Tubing RPTA03 Door RDTH34 RDTH38 RDTH42...
  • Page 49 Appendix Indoor fireplace in protected outdoor applications clearances in the appliance manual must be observed. Framing, Clearances to Combustibles, Mantel Heights, Facing Requirements, Venting Installation, etc. Use supplied Safety Screen. Dimension "A" X .75 Example formula A x 0.75 For example: if at least 63"...
  • Page 50: Appendix A: Venting Terminations

    Appendix Appendix A: Venting Terminations Covered Covered Alcove Detail Alcove Detail Vinyl Siding 2’ 2’ 2’ 2’ 17.5’’ 29.5’’ 11.5’’ 17’’ Must use Vinyl Siding Termination Shield clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches...
  • Page 51: Appendix B: Warranty

    (collectively referred to herein as "The Companies"), warrants the If the components of the appliance covered by this warranty Montigo gas appliance (referred to herein as 'the appliance') to are found to be defective within the time frame stated (see The...
  • Page 52 Montigo dealer (www.Montigo.com) or contact Montigo direct at techsupport@ montigo.com. Ensure you have your sales receipt and the model and serial number of your appliance. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF distributor, you must notify The Companies in writing.
  • Page 53: Appendix C: Amendment (Gas Fireplace / Equipment Sold In The State Of Massachusetts)

    Appendix Appendix C: Amendment (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as 4. INSPECTION. The state or local gas inspector of the side wall follows: horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes Existing chimneys shall be permitted to have their use continued carbon monoxide detectors and signage installed in accordance when a gas conversion burner is installed, and shall be equipped...
  • Page 54 Installation & Maintenance Manual Indoor Direct Vent Gas Fireplace XG0228 - 021419...

Table of Contents