Rear Venting Graph

Measure the vertical height from the fireplace hearth to the centre of
the termination and the horizontal run from the fireplace flue collar to
the wall flange of the termination. Plot on the Venting Graph with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 60" and the horizontal
run to the wall flange of the vent termination is 24", this would be an
acceptable installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 78" and the horizontal
run to the wall flange of the vent termination is 60", this would be an
acceptable installation
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the
horizontal run to the wall flange of the vent termination is 120", this
would NOT be an acceptable installation.
132
120
Acceptable vent run
within non-shaded area.
108
96
84
B
72
A
60
48
50''
36
48''
24
26''
12
18''
0
0
12
24
36
48
60
Figure 9. H*34DF* Rear Vent Venting Graph for wall mounted terminations
XG0146 - 180405
VENT RUN
C
Unacceptable vent run
within shaded area.
72
84
96
108
120
132
144
156
168 180
Horizontal Run (In.)
Hearth
Hearth
Figure 9.b Straight run, Rear Vented, wall mounted termination.
Flex or Rigid
Flex or Rigid
Section
Section
12"
18''
Max.
Max.
Figure 9.c Rear Vented, wall mounted Multi-elbow termination installation. Multi-elbow venting
Installation for H*34DF* must have a minimum vertical rise of 50".The vent run must comply
with the Venting Graph
Installation
NOTE: 18'' MAX horizontal
run with no vertical lift
PXT Extension
MXT Extension
RHS101 Heat
RHS100
Shield
Heat Shield
Termination
Termination
12" MAX.
18'' MAX
26 3/8"
26''
Exterior
Exterior
Wall
Wall
30'' Max.
30" Max.
for minimum
vertical
49" Min NG
50'' Min.
63" Min LP