Store And Assign Emissivity Constants; Select The Emissivity Constant; Further Configuration; Configuration - Signal Conditioning - Siemens Ardoptix PT 140 AF4 Operating Manual

Pt 14 series two-colour pyrometer
Table of Contents

Advertisement

s
Temperature measurement lambda 1 (Configuration layer: C002)
Parameter Function
Enter desired number
E.TB.1
of elements in array

13.1.1 Store and assign emissivity constants

Next, assign a value to each material constant in the index (
02 etc.).
Temperature measurement lambda 1 (Configuration layer:
Parameter Function
Emissivity
E. 01
Memory position 1
Emissivity
E. 02
Memory position 2
Emissivity
E. 03
Memory position 3
13.2

Select the emissivity constant

The memory position can optionally be set using the menu.
Temperature measurement lambda 1 (Configuration layer:
Parameter Function
E.IDX
Memory position
Parameters for lambda 2 are identical to lambda 1. See Chap-
ter 16.1.3
14

Further configuration

15 Configuration – signal conditioning

15.1.1 Transmission factor (spectral mode)

The pyrometer has to be adjusted for the transmission properties of any
supplementary lens and/or protective window screwed onto the pyrome-
ter. Set the pyrometer for the specific transmission factor (a percentage
value) which is indicated either in the product's data sheet or on the lens
itself. This is parameter
C002/C003
layer
window, set the parameter to 100.0.
Explanation
If
▲▼ keys to manually set emis-
sivity
Explanation
z. B. 75 %
z. B. 60 %
z. B. 50 %
Explanation
Shows current selected emissivity constant,
e.g.
TAU.1
and can be accessed at configuration
. If you are not using any auxiliary lens or protective
14
Operating manual
E.TB.1
OFF,
=
E. 02
then use
E. 01
E.
,
C002
)
C002
)