WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
Electrical
1.
The electrical installation must comply with BS 7671 (commonly referred to as
the IEE Wiring Regulations) and all relevant building regulations, or any particular
regulation or practice specified by the local electricity supply company.
2.
Ensure that all circuit protection devices, switches and cabling is adequate
for the rated current of the shower and that the rating of the electricity supply
company fuse and the consumer unit are adequate for the additional demand.
The shower must be earthed. Ensure any supplementary bonding complies
3.
with the relevant regulations.
4.
This shower is intended to be permanently connected to the fixed electrical wiring
of the mains system. A separate supply must be provided from the consumer
unit to the shower.
5.
DO NOT supply any other electrical equipment including extractor fans or pumps
via this product.
6.
This shower must be provided with means for local disconnection that is
incorporated into the fixed wiring in accordance with the relevant local wiring
regulations. This must be a double pole switch, which has at least 3 mm contact
separation in each pole. The switch can be a ceiling mounted pull-cord type within
the shower room or a wall mounted switch fitted in the applicable zone area.
7.
A 30mA Residual Current Device (RCD) is recommended to be incorporated
into the electrical supply to this shower in accordance with wiring regulations.
DO NOT apply excessive force to the terminal block.
8.
9.
All electrical connections should be checked for tightness to prevent overheating
before switching on the electrical supply.
10. DO NOT switch on the electrical supply until the plumbing has been completed
and checked for leaks.