Specifications - Mira Jump 96Va Installation And User Manual

8.5, 9.5, & 10.8 kw
Table of Contents

Advertisement

Plumbing
Minimum Dynamic Pressure
Maximum Dynamic Pressure*
Maximum Static Pressure
Minimum Static Pressure
Maximum Inlet Temperature
Minimum Inlet Temperature
Inlet Connection
Maximum Water Hardness
Outlet Connection
Electrical
Nominal Power at 230 V ac
Nominal Power at 240 V ac
Recommended MCB Rating
Maximum Supply Cable Size
Recommended RCD Rating
Recommended Isolator Switch
Appliance Sealing Rating
Maximum Ambient Temperature
Minimum Ambient Temperature
Dimensions
Height
Width
Depth
*A drop tight pressure reducing valve should be installed where dynamic or static pressure exceeds the
figure stated in the Specifications.
European Conformity Information
The Mira Jump range of showers complies with the following European directives:
2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive.
The Mira Jump range of showers are high power appliances and are subject to conditional connection.
If the main electrical supply fuse is rated less than 80 Amps, the local electricity supply company must
be contacted to confirm if the electrical supply is adequate.
The Mira Jump range of showers complies with the requirements of the UK's water regulations.

SPECIFICATIONS

Jump 8.5
70 kPa
(0.7 bar)
1/2" BSP Male / 15 mm Compression Fitting
Jump 8.5
7.8 kW
8.5 kW
40 A
45 A double-pole with 3 mm contact separation
IP X4 - Suitable for installation in Zone 1
6
Variant
Jump 9.5
70 kPa
(0.7 bar)
500kPa (5 bar)
1000 kPa (10 bar)
50 kPa (0.5 bar)
30°C
2°C
200 ppm CaCO
3
1/2" BSP Male
Variant
Jump 9.5
8.7 kW
9.5 kW
40 A
16 mm²
30 mA tripping current
30°C
2°C
340 mm
228 mm
93 mm
Jump 10.8
100 kPa
(1.0 bar)
Jump 10.8
9.9 kW
10.8 kW
45 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jump 96waJump 96xa

Table of Contents