Caution! If you are unsure how electric showers work, please read the Operation
section before continuing.
1.
Turn the temperature control fully anticlockwise to cold and the heater control
to "LOW".
2.
Switch on the electrical supply at the double pole switch. The power light will
indicate electricity is being supplied to the shower.
3.
Turn the shower on by pressing the start/stop
button.
Check that water flows freely from the shower
within a few seconds. If not, refer to the Fault
Diagnosis section. The water from the handset
should be at full force and at a cool temperature.
4.
Turn the temperature control slowly clockwise
to increase the temperature. The flow will be
reduced and the temperature will remain cool
(this shows that the flow regulator assembly is
operating correctly).
5.
Turn the temperature control back anticlockwise
to fully cold.
6.
Turn the heater control to "ECO". The
temperature of the water should rise slightly.
Allow a few seconds for the warm water to reach the handset - this shows that
the Eco heater setting is operating correctly.
7.
Turn the heater control to "HIGH". The temperature of the water will rise further
- this shows that the maximum heater setting is operating correctly.
8.
Set the shower temperature by rotating the temperature control as necessary.
Turn the control clockwise for warmer water and anticlockwise for cooler water.
Allow approximately 10 seconds for the shower to fully adjust to the required
temperature.
Note! It is normal for the flow rate (shower force) to change when the temperature
is changed. Most changes will go unnoticed.
9.
When the required temperature is reached, press the start/stop button to turn
the shower off. Water will continue to flow from the handset for a few seconds,
as water is cleared from the shower.
10. Switch off the power at the double pole switch. The power light turns off indicating
no electricity to the shower.
Note! A slight hissing sound may be heard from the shower during operation.
High mains water pressure and high shower temperatures will affect the tone.
This is quite normal in use.
COMMISSIONING
16
Heater
Control
Temperature
Control
Start/Stop
Button