Technical specifications of the SM 322; DO 16 x Rel. 120/230 VAC
Dimensions and Weight
Dimensions W x H x D
(in millimeters)
Weight
Data for Specific Module
Supports clocked
operation
Number of outputs
Length of cable
Unshielded
Shielded
Voltages, Currents, Potentials
Rated supply voltage of the
relay L +
Total current of the outputs
(per group)
Isolation
Between channels and
backplane bus
Between the channels
In groups of
Permitted potential difference
Between M
and
internal
supply voltage of the
relays
Between M
and
internal
supply voltage of the
relays and the outputs
Between the outputs of
the different groups
Insulation tested with
Between M
and
internal
supply voltage of the
relays
Between M
and
internal
supply voltage of the
relays and the outputs
Between the outputs of
the different groups
Current consumption
From the backplane bus
From supply voltage L+
Power dissipation of the
module
Status, Interrupts, Diagnostics
Status display
Interrupts
Diagnostic functions
Data for Selecting an Actuator
Continuous thermal current
Minimum load voltage /
current
Short-circuit proof to
IEC 947-5-1
Programmable Logic Controllers S7-300 Module Data
A5E00105505-03
40 x 125 x 117
Approx. 250 g
No
16
max. 600 m
max. 1000 m
24 VDC
max. 8 A
Yes
Yes
8
75 VDC / 60 VAC
230 VAC
500 VAC
500 VDC
1500 VAC
2000 VAC
max. 100 mA
max. 250 mA
typ. 4.5 W
Green LED per channel
None
None
max. 2 A
10 V / 10 mA
200 A, with B10/B16
circuit breaker
Switching capacity and lifetime of the contacts
For resistive load
Voltage
24 VDC
60 VDC
120 VDC
24 VAC
48 VAC
60 VAC
120 VAC
230 VAC
Inductive load according to IEC 947-5-1 DC13/AC15
Voltage
24 VDC
60 VDC
120 VDC
24 VAC
48 VAC
60 VAC
120 VAC
230 VAC
An external protection circuit will enhance the service life
of the contacts.
Size of the motor starter
Lamp load
Contact protection (internal)
Parallel connection of
2 outputs
For redundant triggering
of a load
To increase performance
Triggering a digital input
Switch rate
Mechanical
For resistive load
Inductive loads according
to IEC 947-5-1, DC 13/AC
15
For lamp load
Digital Modules
Current
No. of
switching cyc.
(typ.)
2.0 A
0.1 million
1.0 A
0.2 million
0.5 A
1.0 million
0.5 A
0.2 million
0.2 A
0.6 million
1.5 A
1.5 million
1.5 A
1.5 million
1.5 A
1.5 million
2.0 A
1.0 million
1.0 A
1.5 million
0.5 A
2.0 million
2.0 A
1.0 million
1.0 A
1.5 million
0.5 A
2.0 million
Current
No. of
switching cyc.
(typ.)
2.0 A
0.05 million
1.0 A
0.1 million
0.5 A
0.5 million
0.5 A
0.1 million
0.2 A
0.3 million
1.5 A
1 million
1.5 A
1 million
1.5 A
1 million
2.0 A
0.7 million
1.0 A
1.0 million
0.5 A
1.5 million
2.0 A
0.7 million
1.0 A
1.0 million
0.5 A
1.5 million
max. size 5 to NEMA
50 W / 230 VAC
5 W / 24 VDC
None
Possible (only outputs of
the same group)
Not possible
Possible
max. 10 Hz
1 Hz
max. 0.5 Hz
1 Hz