Component Temperature Measurement

The following sections outline general temperature measurement methods.
For the specific types of measurements required for thermal evaluation of
this board, see

Preparation

We recommend 40 AWG (American wire gauge) thermocouples for all
thermal measurements. Larger gauge thermocouples can wick heat away
from the components and disturb air flowing past the board.
Allow the board to reach thermal equilibrium before taking measurements.
Most circuit boards will reach thermal equilibrium within 30 minutes.
After the warm up period, monitor a small number of components over
time to assure that equilibrium has been reached.

Measuring Junction Temperature

Some components have an on-chip thermal measuring device such as a
thermal diode. For instructions on measuring temperatures using the on-
board device, refer to the component manufacturer's documentation listed
in
Appendix D, Related

Measuring Case Temperature

Measure the case temperature at the center of the top of the component.
Make sure there is good thermal contact between the thermocouple
junction and the component. We recommend you use a thermally
conductive adhesive such as Loctite 384.
If components are covered by mechanical parts such as heatsinks, you will
need to machine these parts to route the thermocouple wire. Make sure that
the thermocouple junction contacts only the electrical component. Also
make sure that heatsinks lay flat on electrical components. The following
figure shows one method of machining a heatsink base to provide a
thermocouple routing path.
http://www.motorola.com/computer/literature