Graco ProMix 2KS Operation Manuals page 35

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Option Screen 2
F
. 31. Option Screen 2
IG
Auto Dump
If the auto dump feature is being used, set to "Solvent
Push" or "Mix Fill Push". Once the auto dump is
enabled, the gun flush box is enabled and the potlife
alarm is active for 2 minutes, the system will automati-
cally flush or push out the old material based on the
selected option.
"Solvent Push" will flush out expired material using the
solvent supply. See Solvent Push Feature on page 65
for more information.
"Mix Fill Push" will push out expired material with new
mixed material. When sufficient material has been
pushed, the potlife alarm will reset. See Mix Fill Push
Feature on page 66 for more information.
Flow Rate Monitor
If set to "On," Recipe Setup Screen 6 on page 43 is
added, enabling setting of high and low flow limits.
If set to "Off," flow rate monitoring is disabled and Rec-
ipe Setup Screen 6 on page 43 will not appear.
Solvent Push Enable
NOTE: See Solvent Push Feature on page 65 for more
information.
To enable the Solvent Push feature, select "Solvent" or
"3rd Valve" (available if 3rd Flush Valve in Configure
Screen 3, page 32, is set to "On").
To disable the Solvent Push feature, set to "Off."
312776K
B Purge After Chop
NOTE: This is used to isolate the Chop cycle from the
Final Purge cycle with solvent to prevent reaction issues
with some types of materials.
Optional 2-second burst (2 s B) operation of the B Purge
valve on the integrator after the Chop cycle.
See Color Change Sequences, page 69 for color
change charts and timing information.
Setup Mode
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix 3ks

Table of Contents