Note
When switching from EVL back to RS-485 mode, all EVL Secondary (DS)
controllers are automatically unregistered from the primary so that they may
be used again as RS-485 DS controllers.
Note
When switching from EVL to RS-485 mode, if the EVL primary can not
communicate with the DS controller, then the DS controller remains an EVL
controller until it is set back to factory defaults.
Note
Switching to RS-485 mode causes deregistration of EVL Secondary
controllers from the primary. Suggestion: Save the configuration database if
you might later switch back to EVL mode.
Configuring for MAXPRO Cloud
1.
Navigate to Host/Loop Communications:
Dashboard > Panels > Host/Loop Communications, or
Menu > Panel Configuration > Host/Loop Communications.
2.
Click to select MAXPRO Cloud.
Figure 2-8
Selecting MAXPRO Cloud on the Host/Loop Communications Tab
3.
Enter the Unique Key and Server URL.