106 |
NetAXS-123 Access Control Unit User's Guide
Remember to return their configuration back to a downstream panel once the upgrade has
been successfully completed.
The firmware and Operating System (OS) can be downloaded from the Honeywell
Download Center at the following site: https://mywebtech.honeywell.com/.
Download the following version numbers:
Supported upgrade from firmware v5.01.07 or higher:
Upgrade Procedure - Download the following file to the NetAXS-123 panel:
1-NetAXS-123_Upgrade_apps06.00.10.xx.bin
Supported upgrade from firmware v 5.0.16 or lower:
Upgrade Procedure - Download the following files to the NetAXS-123 panel in the
following order:
1-NetAXS-123_Upgrade_apps06.00.10.xx.bridge.bin
2-NetAXS-123_Upgrade_OS107_R5.1-or-later.bin

Reverting to a Different Firmware Version

1.
www.honeywell.com/security
Note
If required after the NetAXS-123 v6.0 upgrade the user can toggle to the
"InActive" Firmware set of the previous version that incorporates NetAXS-123
Firmware 5.X or lower. Then restore the NetAXs-123 V 5.X or lower backup
into the v5.X "Active" set and then toggle to the "InActive" v6.0 Firmware set.
Navigate to the Settings panel:
• Dashboard > Panels > Settings, or
• Menu > Panel Configuration > Settings.

Hide quick links:

Advertisement

Table of Contents