Configure the following general settings.
Configuration
Description
Pulse
Specifies the duration for which the device will assume abnormal
status. For example, it specifies how long a horn will sound or a
door strike will remain released. The maximum length of time is 1
hour, 45 minutes, 59 seconds.
You can express seconds in tenths of a second.
Latch
Toggles the state of the outputs between energized and
de-energized status upon every activation (code use, interlock, or
manual pulse).
Interlocks
Enables you to disable the interlock, or programmed interaction
between two points. When enabled, this point ignores all interlock
actions to it, effectively disabling it from being a Reacting
Component.
TZ Card Toggle
Requires, like the First Card Rule, a valid card read within the
schedule to enable the schedule (period in which doors are
unlocked) to take effect. Unlike the First Card Rule, however, the
user can swipe the card a second time to return the doors to a
locked state.
Note
First Card Rule
Requires a valid card read within the schedule to enable the
schedule (period in which doors are unlocked) to take effect.
Note
Configure the following schedule settings.
Configuration
Description
Energized
Sets the period during which the output is automatically
energized.
Disable
Sets the period during which the interlock, a programmed
Interlocks
interaction between selected inputs, outputs, and groups will be
disabled. During the selected Schedule, this point ignores all
interlock actions to it, effectively disabling it from being a
Reacting Component during the Schedule. Outside of the
Schedule the point will react to interlocks as expected.
Click Save.
Both TZ Card Toggle and First Card Rule cannot be
enabled at the same time. Appears only on door lock
outputs.
Both TZ Card Toggle and First Card Rule cannot be
enabled at the same time. Appears only on door lock
outputs.