Setting the Communication Mode to Web
1.
2.
3.
Table 2-5
Web Host Communication Mode Settings
Host
Setting
Mode
Time Sync
Baud Rate
4.
www.honeywell.com/security
Navigate to Host/Loop Communications:
Dashboard > Panels > Host/Loop Communications, or
Menu > Panel Configuration > Host/Loop Communications.
Click to select Web.
Figure 2-7
Selecting WEB on the Host/Loop Communications Tab
Configure the host settings.
Click Save.
Description
RS-485 - If Primary provides access to RS-485 Loop.
EVL - If Primary provides access to Ethernet Virtual Loop.
Synchronizes the primary's time with the secondary
panels.
Enabled – Time-synchronizes the loop by automatically
broadcasting the primary's time to secondary panels.
Select from 60-32767 minutes.
Specifies the transmission rate (bits per second) among
the secondary panels on the loop.
Force Baud Reset – Tells all secondary panels to change to
the selected loop baud rate. This saves the user from
having to go to each panel individually.