Synchronization Detail Chart

Synchronization

Primary panel to the Secondary panel synchronization occurs at the time the Secondary
panels are "Registered" with the Primary.
The Synchronization only occurs at the time of panel registration and will include Common
Data.
The Secondary panel will reboot after synchronization.
Example:
Primary to Secondary Synchronization in following order with (3) Secondary Panels:
1.
2.
3.
Common data includes:

Access control behavior during synchronization:

The 1st Secondary panel will receive the backup and reboot.
The 2nd Secondary panel will receive the backup and reboot
The 3rd Secondary panel will receive the backup and reboot.
• Schedules
• Cards
• Card Formats
• Holidays
• Access Group Name (access group details are panel-specific)
• Configuration (Site Codes)
• Primary Panel access control not affected.
• Newly registered secondary panels will show online in Web Interface and will
keep its existing card and common config. Once common data received,
secondary's access control and communication processes stop running and
the existing common data will be overwritten by new one from primary. Once
the common data is received the Secondary panel will reboot.
• Approximate 4 minutes for secondary panel access control to function after
registration and synchronization.