mabe Kraken Service Manual page 72

Top load washer 27"
Table of Contents

Advertisement

Fault
Name
Description
Code
(Hex)
22
Out of
Large wet/OOB
Balance
load being washed.
(OOB)
This is set if OOB
during
condition is
Dry Load
detected during dry
Sense.
load sense
algorithm. Dry load
sense will be
abandoned and wet
load sense will be
started.
23
Critical
1. Lock blockage.
Lid Lock
2. Lid Lock failure.
Will not lock or
unlock or is locked
while lid is opened.
24
Lid Logic
Lid switch failure.
Failure
This fault is sent if
the system
perceives the lid to
be both OPEN and
LOCKED for 5
consecutive
seconds.
Ingeniería de Servicio
Fault Codes
Repair Action
1. Check for excessively OOB load. Customer
Education on how to distribute load.
2. Check the basket for excessive friction or
for being excessively out of round. Basket
should spin freely and without wobble. If
friction is found, remove it. If basket is bad
replace it.
 Verify that the lid lock is not blocked by any
external debris.
 Check lid switch continuity at J513 on the
control.
 Check continuity of lid lock position. Opened
or Closed.
 Check for proper operation of lid lock. 120
VAC while activating.
 Check lid lock wiring harness from the
control to lock assembly.
 If lid lock assembly and harness are OK,
replace control board.
1. Check harness and connections from the
control to the lid lock assembly for damage
and continuity.
2. Run a spin cycle. Pull up on the lid during
spin for more than 5 seconds and see if this
fault occurs. Replace lid lock assemble.
3. If above does not correct the fault, replace
the control.
- 72 -