Fault
Name
Description
Code
(Hex)
4
Reset
Control is resetting
Monito
the software by itself
r
due to criteria it
believes could
resolve itself upon
reset.
Control didn't see the
5
Mode
Shifter
transition from Agitate
ti Spin or vice-versa
in the time required.
Could mean the shift
didn't occur or
Control didn't get the
signal because of
lack of connection
6
Critical
Control received an
Flood
extended period of
Level
pressure readings
by
that is nearing over-
Pressu
flow levels. Pressure
17.5".
re.
Pressu
Voltage Output must
re level
be present. Could
exceed
mean water did get
s 17.5
that high due to
inches
briefly stuck water
above
valve. Voltage output
pressu
of sensor too high for
re port.
actual water level
because of sensor or
water in pressure
tube increasing
pressure.
Ingeniería de Servicio
Fault Codes
Repair Action
 Check for loose connections at the control.
Reconnect if any.
 Check for recommended house line voltage
to the washer.
 Check mode shifter coupler for damage and
the ability to slide in and out freely.
 Using an Ohm meter, check to ensure mode
shifter switch is in the open position.
 Check resistance of mode shifter motor
(approximately 5,700 ohms)
 Check for 120 VAC to the mode shifter motor
at the control J512 connector.
 If voltage is present, replace the mode shifter.
 If voltage is not present at the control, replace
control.
 Check pressure tube for pinches where it
goes through top cover grommet.
 Check pressure tube for trapped water.
 Check for any leaking water valves.
 Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.
- 64 -