mabe Kraken Service Manual page 59

Top load washer 27"
Table of Contents

Advertisement

Knob Index / Test
number (Displayed
on SSD, 7-segment
display, if present)
(Without SSD will
be displayed in
binary format. (See
Binary Chart)
5
6
7
Ingeniería de Servicio
Service Mode Tests
Description of test
If tests call for numbers to be shown it will:
(Display on SSD, 7-segment display, if present)
(Without SSD will be displayed in binary format.
Test Name
(See Binary Chart) Turning the cycle knob will
index to the next or prior test.
XML Version
Example: v01.23
(Non-Critical)
High end UI
press – "01" on SSD
st
1
press – "23" on SSD
nd
2
Low end UI (See Version Diagram below)
Major version (Pause LED ON)
press – Display 0 in binary (all LEDs off)
st
1
press – Display 1 in binary
nd
2
Minor version (Lid Locked LED ON)
press – Display 2 in binary
rd
3
press – Display 3 in binary
th
4
NOTE: We only show the non-critical version
number because the critical XML version number
must match the application non-critical version
number for the control to boot. If you get to
service mode, then the XML critical version is
correct. If not, update software.
Hot Water
Pressing Start will toggle the hot water valve on
Valve
and off. Test will have a timeout for how long
valve will be on (1 minute). The valve will turn off
when the test is exited.
Cold Water
Pressing Start will toggle the cold water valve on
Valve
and off. Test will have a timeout for how long
valve will be on (1 minute). The valve will turn off
when the test is exited.