mabe Kraken Service Manual page 71

Top load washer 27"
Table of Contents

Advertisement

Fault
Name
Description
Code
(Hex)
20
Critical
Water volume into
Flood
the tub exceeded 41
Level by
gallons as calculated
Gallons
by the control.
1. Pressure tube is
momentarily
pinched, has water in
it, partial blockage if
Flood fault 12
occurs.
2. Low water
pressure/flow or
permanent pressure
system blockage if
NO Flood fault 12
occurs.
21
Flood
Water volume into
Warning
the tub exceeded
Level by
36.3 gallons as
Gallons
calculated by the
control. Stops filling.
1. Pressure tube is
momentarily pinched
or has water in it,
partial blockage if
Flood fault 6, 7, or 12
occurs.
2. Low water
pressure/flow or
permanent pressure
system blockage if
NO Flood fault 6, 7,
or 12 occurs.
Ingeniería de Servicio
Fault Codes
Repair Action
 Check pressure tube for pinches where it
goes through top cover grommet.
 Check pressure tube for trapped water.
 Check for any leaking water valves.
 Check home water pressure.
 Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart, if it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.
 Check pressure tube for pinches where it
goes through top cover grommet.
 Check pressure tube for trapped water.
 Check for any leaking water valves.
 Check home water pressure.
 Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart, if it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.
- 71 -

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for mabe Kraken

Table of Contents