mabe Kraken Service Manual page 70

Top load washer 27"
Table of Contents

Advertisement

Fault
Name
Description
Code
(Hex)
18
Drain
While draining the
Pump
pressure sensor
Clearing
value for water level
algorith
did not indicate the
m failed.
washer was empty
before the Max
Continuous Drain
ON time was
reached.
19
UI State
Washer was paused
Timeout
for over 12 hours
Ingeniería de Servicio
Fault Codes
Repair Action
 This fault is set and will be seen with fault 16
when Drain Pump Clearing Algorithm failed to
remove the blockage and the rest of water in
tub.
 Check the drain pump for blockage.
 Check installation instructions for proper
standpipe height.
 Check pressure tube for pinches where it
goes through top cover grommet.
 Check pressure tube for trapped water.
 Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.
 Check resistance of the pump (13.2 ohms)
from J512 connector on the control.
 If open circuit, check wiring harness to the
pump and pump motor.
 Check for 120 VAC to the drain pump.
 If voltage is present and pump does not
operate, replace pump.
 If voltage is not present, replace IMC
(Interface Machine Control).
 This is normal operation. This will happen if
the consumer and or control switched cycle to
a paused state.
- 70 -