mabe Kraken Service Manual page 65

Top load washer 27"
Table of Contents

Advertisement

Fault
Name
Description
Code
(Hex)
7
Flood
Main micro received
Warnin
and extended period
g Level
of pressure readings
by
that is greater than
Pressu
maximum allowable
re.
fill volume. Pressure
16.5". Voltage output
Pressu
re level
must be present.
exceed
Could mean water did
s 16.5
get that high due to
inches
briefly stuck water
above
valve. Voltage output
pressu
of sensor too high for
re port.
actual water level
because of sensor or
water in pressure
tube increasing
pressure.
Ingeniería de Servicio
Fault Codes
Repair Action
 This can happen if a large wet load is placed
in the washer.
 Check pressure tube for pinches where it
goes through top cover grommet.
 Check pressure tube for trapped water.
 Check for any leaking water valves.
 Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.