mabe Kraken Service Manual page 67

Top load washer 27"
Table of Contents

Advertisement

Fault
Name
Description
Code
(Hex)
10
Mode
Signal feedback state
Shift
from the mode shifter
Feedb
(agitate or spin) and
ack
the state requested by
Monito
the control are not the
r
same and the basket
or agitator is rotating
faster than 3-4 RPM.
Agitate mode
feedback signal is no
voltage.
11
Clock
1. AC power line
Monito
frequency is not 60
r
Hz.
2. Software failure.
12
Redun
Backup Processor
dant
received an extended
Flood
period of pressure
Conditi
readings that is
on
nearing over-flow
levels.
Pressure 18.0"
Voltage Output must
be present. Could
mean water did get
that high due to briefly
stuck water valve.
Voltage output of
Sensor too high for
actual water level
because of Sensor or
water in Pressure tube
increasing pressure.
Ingeniería de Servicio
Fault Codes
Repair Action
 Check mode shifter coupler for damage and
the ability to slide in and out freely.
 Use ohm meter to ensure harness shows
continuity to the mode shifter from the
control..
 Check resistance of mode shifter motor
(approximately 5.7 K ohms)
 Check for 120 VAC to the mode shifter motor
at the control J512 connector.
 If voltage is present and no operation,
replace the mode shifter.
 If voltage is not present at the control,
replace control.
 Check the frequency of the AC power outlet.
If it is more than a few Hz off of 60 Hz.
 If house frequency is good, update software.
 Check pressure tube for trapped water.
 Check each valves Operation... Replace
Water Valve.
 Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.
 If the pressure tube is intact, replace control.
- 67 -