6.0 Connecting to the Control host
1.
Connect to the Control host through the Console Serial port (see 6.1 "Connecting the Console Serial port")
OR the Ethernet management interface (see 6.2 "Connecting the Ethernet management interface").
The IP address of the management port is 192.168.200.10/24. If it is not possible to connect to the
management port via IP, use the serial cable to connect to the SmartNode Control host for the first time.
Default HOSTNAME is the Control host serial number, which can be found in the "Important Notice" sheet
2.
included with your shipment.
Refer to the "Important Notice" sheet for the username and password to log onto the Control host. Navi-
3.
gate to: HTTP://HOSTNAME:12358, to configure the SmartNode unit. (username/password: root/root)
6.1 Connecting the Console Serial port
Connect the supplied CAT5 RJ-45 (male-male) cable between the COM port of your computer and the
1.
serial port (labeled 1010) of the SN10100.
2.
If your computer's serial port features a DB9 connector, use the DB9 to RJ-45 adapter supplied with your
SN10100. If your computer's serial port features a USB connector, you will need to provide a USB to DB9
adapter.

6.2 Connecting the Ethernet management interface

Connect the supplied CAT5 Ethernet cable to the management port labeled Ethernet on the front of the
1.
SN10100.
SmartNode 10100 Series Quick Start Guide
Figure 6.
Computer to the Console Serial port
7