3.17. FUSES

· Never touch places other than those specified. Touching places other than those
specified can cause electric shock and short circuit. Disconnect the machine from
the supply before attempting the replacement of any fuse.
· Only QUALIFIED SERVICE PERSONNEL should replace FUSES.
· Only replace fuses with ones of the same value and type.
There are a number of fuses used on this machine to protect the user and the machine from damage. Only
replace the fuse once you have removed the cause of its failure. Detailed below is a list of the fuses used,
their location and if relevant PCB reference:
PART NUMBER
514-5078-3150
STEREO AMP REF. F1, F2
514-5078-4000
SWITCH REG REF. F1
514-5078-5000
IEC INLET REF. F1
838-11856CE-02
CONN. BD. REF. F1
There are also fuses located on the Monitor PCB. Refer to the relevant Monitor manual supplied to
reference these fuses.
LOCATION
5x20mm CERAMIC SB 3.15A
5x20mm CERAMIC SB 4A
5x20mm CERAMIC SB 5A
5x20mm CERAMIC SB 6.3A